Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
43
matching recommendationsSIC | 36 | Electronic & Other Electric Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0323 # 03 Y:1987 | 03 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,055 | $1,200 | Implemented |
TN0323 # 04 Y:1987 | 04 | 1987 | IMPROVE LUBRICATION PRACTICES | $747 | $0 | Not Implemented |
TN0323 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $11,914 | $0 | Implemented |
TN0323 # 02 Y:1987 | 02 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,487 | $520 | Implemented |
TN0312 # 06 Y:1987 | 06 | 1987 | INSTALL SET-BACK TIMERS | $840 | $0 | Implemented |
TN0312 # 04 Y:1987 | 04 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $983 | $0 | Implemented |
TN0312 # 05 Y:1987 | 05 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,716 | $400 | Implemented |
TN0312 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $801 | $150 | Implemented |
TN0312 # 02 Y:1987 | 02 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $1,752 | $4,752 | Not Implemented |
TN0312 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $17,914 | $0 | Implemented |
TN0308 # 07 Y:1987 | 07 | 1987 | OPTIMIZE PLANT POWER FACTOR | $1,764 | $6,800 | Implemented |
TN0308 # 06 Y:1987 | 06 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $950 | $470 | Implemented |
TN0308 # 01 Y:1987 | 01 | 1987 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $14,834 | $0 | Not Implemented |
TN0308 # 05 Y:1987 | 05 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,709 | $165 | Implemented |
TN0308 # 04 Y:1987 | 04 | 1987 | INSULATE BARE EQUIPMENT | $603 | $1,440 | Implemented |
TN0308 # 03 Y:1987 | 03 | 1987 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $2,858 | $3,500 | Not Implemented |
TN0308 # 02 Y:1987 | 02 | 1987 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $5,468 | $16,872 | Not Implemented |
TN0301 # 03 Y:1987 | 03 | 1987 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $3,200 | $400 | Implemented |
TN0301 # 05 Y:1987 | 05 | 1987 | INSTALL SET-BACK TIMERS | $320 | $445 | Not Implemented |
TN0301 # 04 Y:1987 | 04 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,618 | $75 | Implemented |
TN0301 # 01 Y:1987 | 01 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,386 | $6,000 | Implemented |
TN0301 # 02 Y:1987 | 02 | 1987 | SHUT OFF PILOTS IN STANDBY EQUIPMENT | $1,628 | $0 | Implemented |
TN0303 # 08 Y:1987 | 08 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,815 | $720 | Implemented |
TN0303 # 09 Y:1987 | 09 | 1987 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $661 | $348 | Implemented |
TN0303 # 10 Y:1987 | 10 | 1987 | INSTALL / REPAIR INSULATION ON STEAM LINES | $124 | $231 | Not Implemented |