Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1988
Principal Product PREFABRICATED STEEL
NAICS n/a
SIC 3448 - Prefabricated Metal Buildings
Sales $10,000,000-$50,000,000
# of Employees 148
Plant Area (Sq.Ft.) 0
Annual Production 15,300 Tons
Production Hrs. Annual 5,200
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $74,160 1,258,499 kWh $0.06
Natural Gas $13,624 3,352 MMBtu $4.06
TOTAL ENERGY COSTS $87,784
RECOMMENDED SAVINGS* $9,491 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,001
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,470
Cost:
$150
$3,470 83,822 - - $3,470
83,822
kWh
-
-
MMBtu
02: 2.7245 USE DIRECT AIR SUPPLY TO EXHAUST HOODS Savings:
$1,935
Cost:
$10,000
- - $1,935 477 -
-
kWh
$1,935
477
MMBtu
03: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$1,325
Cost:
$1,200
$1,325 31,946 - - $1,325
31,946
kWh
-
-
MMBtu
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$1,145
Cost:
$1,000
- - $1,145 282 -
-
kWh
$1,145
282
MMBtu
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$520
Cost:
$520
$520 12,603 - - $520
12,603
kWh
-
-
MMBtu
06: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$438
Cost:
$150
- - $438 108 -
-
kWh
$438
108
MMBtu
07: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$400
Cost:
$1,000
$260 3,517 $140 64 $260
3,517
kWh
$140
64
MMBtu
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$76
Cost:
$220
$76 1,172 - - $76
1,172
kWh
-
-
MMBtu
09: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$182
Cost:
-
$182 4,396 - - $182
4,396
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$9,491
Cost:
$14,240
$5,833 137,456 $3,658 931 $5,833
137,456
kWh
$3,658
931
MMBtu
TOTAL IMPLEMENTED Savings:
$6,001
Cost:
$10,890
$4,066 97,597 $1,935 477 $4,066
97,597
kWh
$1,935
477
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas