Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1990
Principal Product HYDRAULIC EQUIPMENT
NAICS n/a
SIC 3537 - Industrial Trucks And Tractors
Sales $10,000,000-$50,000,000
# of Employees 125
Plant Area (Sq.Ft.) 0
Annual Production 1,500 Pieces
Production Hrs. Annual 4,692
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $119,791 1,997,655 kWh $0.06
Natural Gas $48,561 10,135 MMBtu $4.79
Fuel Oil #1 $4,100 500 MMBtu $8.20
TOTAL ENERGY COSTS $172,452
RECOMMENDED SAVINGS* $18,200 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,470
#|Description Savings
Cost
Status Electricity Usage Natural Gas Fuel Oil #1 Electricity Usage Natural Gas Fuel Oil #1
$ kWh $ MMBtu $ MMBtu
01: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$6,080
Cost:
$14,110
$6,080 131,008 - - - - $6,080
131,008
kWh
-
-
MMBtu
-
-
MMBtu
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,360
Cost:
$2,000
$3,360 72,392 - - - - $3,360
72,392
kWh
-
-
MMBtu
-
-
MMBtu
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$3,730
Cost:
$12,000
$(-3,790) (-82,063) $7,520 1,570 - - $(-3,790)
(-82,063)
kWh
$7,520
1,570
MMBtu
-
-
MMBtu
04: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$2,824
Cost:
$2,150
- - $(-2,391) (-499) $5,215 499 -
-
kWh
$(-2,391)
(-499)
MMBtu
$5,215
499
MMBtu
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,380
Cost:
-
$1,380 29,601 - - - - $1,380
29,601
kWh
-
-
MMBtu
-
-
MMBtu
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$206
Cost:
$208
$206 2,931 - - - - $206
2,931
kWh
-
-
MMBtu
-
-
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$620
Cost:
$600
$620 13,189 - - - - $620
13,189
kWh
-
-
MMBtu
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$18,200
Cost:
$31,068
$7,856 167,058 $5,129 1,071 $5,215 499 $7,856
167,058
kWh
$5,129
1,071
MMBtu
$5,215
499
MMBtu
TOTAL IMPLEMENTED Savings:
$14,470
Cost:
$19,068
$11,646 249,121 $(-2,391) (-499) $5,215 499 $11,646
249,121
kWh
$(-2,391)
(-499)
MMBtu
$5,215
499
MMBtu
Savings
Cost
$ kWh $ MMBtu $ MMBtu
Electricity Usage Natural Gas Fuel Oil #1 Electricity Usage Natural Gas Fuel Oil #1