Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1990
Principal Product AGRICULTURE MACHINERY
NAICS n/a
SIC 3423 - Hand And Edge Tools, Nec
Sales $10,000,000-$50,000,000
# of Employees 170
Plant Area (Sq.Ft.) 0
Annual Production 22,690 Pieces
Production Hrs. Annual 2,265
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,147 1,089,390 kWh $0.08
Natural Gas $617 69 MMBtu $8.94
TOTAL ENERGY COSTS $91,764
RECOMMENDED SAVINGS* $8,946 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $8,123
#|Description Savings
Cost
Status Electricity Usage Administrative Changes Electricity Usage Administrative Changes
$ kWh $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,500
Cost:
$9,570
$3,110 41,911 $390 - $3,110
41,911
kWh
$390
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,530
Cost:
$7,140
$1,530 48,066 - - $1,530
48,066
kWh
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,330
Cost:
$960
$1,330 26,671 - - $1,330
26,671
kWh
-
-
$
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$660
Cost:
-
$660 - - - $660
-
kWh
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$86
Cost:
$74
$86 1,172 - - $86
1,172
kWh
-
-
$
06: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$423
Cost:
-
$423 8,499 - - $423
8,499
kWh
-
-
$
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$407
Cost:
$480
$407 8,206 - - $407
8,206
kWh
-
-
$
08: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$400
Cost:
-
$400 7,913 - - $400
7,913
kWh
-
-
$
09: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$240
Cost:
-
$240 4,689 - - $240
4,689
kWh
-
-
$
10: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$210
Cost:
$200
$210 4,103 - - $210
4,103
kWh
-
-
$
11: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$160
Cost:
-
$160 3,224 - - $160
3,224
kWh
-
-
$
TOTAL RECOMMENDED Savings:
$8,946
Cost:
$18,424
$8,556 154,454 $390 - $8,556
154,454
kWh
$390
-
$
TOTAL IMPLEMENTED Savings:
$8,123
Cost:
$18,424
$7,733 138,042 $390 - $7,733
138,042
kWh
$390
-
$
Savings
Cost
$ kWh $ $