IAC logo
IAC Assessment: AM0112
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0112
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1991
Principal Product HARD CANDIES
NAICS n/a
SIC 2064 - Candy & Other Confectionery Products
Sales $10,000,000-$50,000,000
# of Employees 160
Plant Area (Sq.Ft.) 0
Annual Production 1,800,000 Pounds
Production Hrs. Annual 4,335
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $128,565 2,604,045 kWh $0.05
Natural Gas $60,950 24,439 MMBtu $2.49
TOTAL ENERGY COSTS $189,515
RECOMMENDED SAVINGS* $11,575 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.1242 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT Savings:
$2,470
Cost:
$5,000
- - $2,470 990 -
-
kWh
$2,470
990
MMBtu
02: 2.2422 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM Savings:
$4,670
Cost:
$19,000
$(-610) (-8,792) $5,280 2,120 $(-610)
(-8,792)
kWh
$5,280
2,120
MMBtu
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$3,900
Cost:
$365
- - $3,900 1,600 -
-
kWh
$3,900
1,600
MMBtu
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES Savings:
$340
Cost:
$310
- - $340 137 -
-
kWh
$340
137
MMBtu
05: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES Savings:
$195
Cost:
$235
- - $195 78 -
-
kWh
$195
78
MMBtu
TOTAL RECOMMENDED Savings:
$11,575
Cost:
$24,910
$(-610) (-8,792) $12,185 4,925 $(-610)
(-8,792)
kWh
$12,185
4,925
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas