IAC logo
IAC Assessment: AM0130
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0130
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 1991
Principal Product DOOR JAMS, STEPS, & TRIM
NAICS n/a
SIC 2431 - Millwork
Sales $10,000,000-$50,000,000
# of Employees 320
Plant Area (Sq.Ft.) 0
Annual Production 11,000 Thousand Feet
Production Hrs. Annual 4,310
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $140,503 1,869,871 kWh $0.08
TOTAL ENERGY COSTS $140,503
RECOMMENDED SAVINGS* $21,427 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.4131 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY Savings:
$9,280
Cost:
$19,700
$9,280 128,957 $9,280
128,957
kWh
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$1,148
Cost:
$653
$1,148 15,826 $1,148
15,826
kWh
03: 2.5121 REDESIGN FLOW TO MINIMIZE MASS TRANSFER LENGTH Savings:
$4,979
Cost:
$16,000
$4,979 66,237 $4,979
66,237
kWh
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$3,370
Cost:
-
$3,370 65,064 $3,370
65,064
kWh
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,161
Cost:
$500
$1,161 22,567 $1,161
22,567
kWh
06: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$1,109
Cost:
-
$1,109 15,240 $1,109
15,240
kWh
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$240
Cost:
-
$240 4,689 $240
4,689
kWh
08: 2.7133 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE Savings:
$140
Cost:
$55
$140 1,465 $140
1,465
kWh
TOTAL RECOMMENDED Savings:
$21,427
Cost:
$36,908
$21,427 320,045 $21,427
320,045
kWh
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - -
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage