Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1996 |
Principal Product | Grinding & electroplating of metals, hard chrome and electro |
NAICS | n/a |
SIC | 3471 - Plating And Polishing |
Sales | $1,000,000-$5,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 101,744 Thousand Feet |
Production Hrs. Annual | 4,016 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $135,351 | 3,234,467 | kWh | $0.04 |
Electricity Demand | $56,804 | 8,539 | kW-months/year | $6.65 |
Electricity Fees | $6,360 | - | $ | - |
Natural Gas | $88,959 | 17,289 | MMBtu | $5.15 |
TOTAL ENERGY COSTS | $293,694 | |||
RECOMMENDED SAVINGS* | $18,440 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $8,310 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,920 Cost: $9,040 |
$1,400 | 63,599 | $2,520 | 205 | - | - | - | - |
$1,400 63,599 kWh |
$2,520 205 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $2,800 Cost: $110 |
- | - | - | - | $2,800 | 543 | - | - |
- - kWh |
- - kW-months/year |
$2,800 543 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $1,480 Cost: $770 |
$530 | 24,326 | $950 | 77 | - | - | - | - |
$530 24,326 kWh |
$950 77 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,350 Cost: $500 |
- | - | - | - | $1,350 | 264 | - | - |
- - kWh |
- - kW-months/year |
$1,350 264 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,150 Cost: $200 |
$1,150 | 52,169 | - | - | - | - | - | - |
$1,150 52,169 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,030 Cost: $850 |
- | - | - | - | $1,030 | 200 | - | - |
- - kWh |
- - kW-months/year |
$1,030 200 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $510 Cost: $175 |
$190 | 8,792 | $320 | 26 | - | - | - | - |
$190 8,792 kWh |
$320 26 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $260 Cost: $110 |
$60 | 2,931 | $200 | 16 | - | - | - | - |
$60 2,931 kWh |
$200 16 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $90 Cost: $180 |
$30 | 1,465 | $60 | 5 | - | - | - | - |
$30 1,465 kWh |
$60 5 kW-months/year |
- - MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $5,850 Cost: $40,000 |
- | - | - | - | - | - | $5,850 | 122,400 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,850 122,400 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,440 Cost: $51,935 |
$3,360 | 153,282 | $4,050 | 329 | $5,180 | 1,007 | $5,850 | 122,400 | $3,360 153,282 kWh |
$4,050 329 kW-months/year |
$5,180 1,007 MMBtu |
$5,850 122,400 gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $8,310 Cost: $11,055 |
$2,830 | 128,956 | $3,100 | 252 | $2,380 | 464 | - | - | $2,830 128,956 kWh |
$3,100 252 kW-months/year |
$2,380 464 MMBtu |
- - gal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) |