Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 1997 |
Principal Product | Corrugated fiberboard sheets |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 1,000,000 Thousand Feet |
Production Hrs. Annual | 4,554 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $83,111 | 2,280,188 | kWh | $0.04 |
Electricity Demand | $41,993 | 5,115 | kW-months/year | $8.21 |
Electricity Fees | $168 | - | $ | - |
Natural Gas | $213,482 | 60,500 | MMBtu | $3.53 |
TOTAL ENERGY COSTS | $338,754 | |||
RECOMMENDED SAVINGS* | $19,610 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,460 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $7,000 Cost: $4,100 |
- | - | - | - | - | - | $7,000 | 15,500,000 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$7,000 15,500,000 Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $3,100 Cost: $5,630 |
- | - | - | - | $3,100 | 880 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,100 880 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $2,150 Cost: $1,290 |
$950 | 36,342 | $1,200 | 96 | - | - | - | - | - | - |
$950 36,342 kWh |
$1,200 96 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $2,100 Cost: $2,500 |
- | - | - | - | - | - | - | - | $2,100 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$2,100 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $1,980 Cost: $210 |
- | - | - | - | $1,980 | 559 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,980 559 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,860 Cost: $780 |
$520 | 20,223 | $1,340 | 106 | - | - | - | - | - | - |
$520 20,223 kWh |
$1,340 106 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $1,060 Cost: $500 |
- | - | - | - | $1,060 | 301 | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,060 301 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $360 Cost: $25 |
$160 | 6,155 | $200 | 16 | - | - | - | - | - | - |
$160 6,155 kWh |
$200 16 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $19,610 Cost: $15,035 |
$1,630 | 62,720 | $2,740 | 218 | $6,140 | 1,740 | $7,000 | 15,500,000 | $2,100 | - | $1,630 62,720 kWh |
$2,740 218 kW-months/year |
$6,140 1,740 MMBtu |
$7,000 15,500,000 Tgal |
$2,100 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,460 Cost: $13,745 |
$680 | 26,378 | $1,540 | 122 | $6,140 | 1,740 | $7,000 | 15,500,000 | $2,100 | - | $680 26,378 kWh |
$1,540 122 kW-months/year |
$6,140 1,740 MMBtu |
$7,000 15,500,000 Tgal |
$2,100 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption |