Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2000
Principal Product Refrigeration and other control valves
NAICS n/a
SIC 3491 - Industrial Valves
Sales $10,000,000-$50,000,000
# of Employees 215
Plant Area (Sq.Ft.) 50,000
Annual Production 1,750,000 Pounds
Production Hrs. Annual 5,072
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,765 1,987,397 kWh $0.05
Electricity Demand $17,641 5,428 kW-months/year $3.25
Natural Gas $6,019 1,439 MMBtu $4.18
TOTAL ENERGY COSTS $128,275
RECOMMENDED SAVINGS* $20,535 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $6,255
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Other Liquid (haz) Personnel Changes Electricity Usage Electricity Demand Other Liquid (haz) Personnel Changes
$ kWh $ kW-months/year $ gal $ $
01: 3.7191 USE WATER BASED SPRAY ABRASIVES INSTEAD OF BAR ABRASIVES Savings:
$13,500
Cost:
$70,000
- - - - $13,500 10,100 - - -
-
kWh
-
-
kW-months/year
$13,500
10,100
gal
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,540
Cost:
$500
$4,540 105,510 - - - - - - $4,540
105,510
kWh
-
-
kW-months/year
-
-
gal
-
-
$
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,245
Cost:
$210
$1,000 23,154 $245 55 - - - - $1,000
23,154
kWh
$245
55
kW-months/year
-
-
gal
-
-
$
04: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$600
Cost:
$180
$600 13,775 - - - - - - $600
13,775
kWh
-
-
kW-months/year
-
-
gal
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$470
Cost:
$215
$60 1,465 $10 2 - - $400 - $60
1,465
kWh
$10
2
kW-months/year
-
-
gal
$400
-
$
06: 2.4314 USE SYNTHETIC LUBRICANT Savings:
$180
Cost:
-
$145 3,224 $35 8 - - - - $145
3,224
kWh
$35
8
kW-months/year
-
-
gal
-
-
$
TOTAL RECOMMENDED Savings:
$20,535
Cost:
$71,105
$6,345 147,128 $290 65 $13,500 10,100 $400 - $6,345
147,128
kWh
$290
65
kW-months/year
$13,500
10,100
gal
$400
-
$
TOTAL IMPLEMENTED Savings:
$6,255
Cost:
$925
$5,600 130,129 $255 57 - - $400 - $5,600
130,129
kWh
$255
57
kW-months/year
-
-
gal
$400
-
$
Savings
Cost
$ kWh $ kW-months/year $ gal $ $
Electricity Usage Electricity Demand Other Liquid (haz) Personnel Changes Electricity Usage Electricity Demand Other Liquid (haz) Personnel Changes