Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2000 |
Principal Product | Clay bricks |
NAICS | n/a |
SIC | 3251 - Brick And Structural Clay Tile |
Sales | $5,000,000-$10,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 104,850 |
Annual Production | 33,000,000 Pieces |
Production Hrs. Annual | 8,670 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $87,761 | 2,530,774 | kWh | $0.03 |
Electricity Demand | $37,138 | 4,846 | kW-months/year | $7.66 |
Natural Gas | $380,679 | 146,532 | MMBtu | $2.60 |
TOTAL ENERGY COSTS | $505,578 | |||
RECOMMENDED SAVINGS* | $8,955 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,150 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $4,070 Cost: $2,740 |
- | - | - | - | $4,070 | 1,566 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,070 1,566 MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,090 Cost: $8 |
$360 | 14,068 | $730 | 70 | - | - | - | - | - | - | - | - |
$360 14,068 kWh |
$730 70 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $950 Cost: $850 |
$200 | 7,913 | $440 | 42 | - | - | - | - | - | - | $310 | - |
$200 7,913 kWh |
$440 42 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$310 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $930 Cost: $200 |
- | - | - | - | - | - | - | - | $930 | 13,230 | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
$930 13,230 lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES |
Savings: $875 Cost: $1,030 |
- | - | - | - | - | - | $875 | 467 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$875 467 gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $660 Cost: - |
$230 | 8,792 | $430 | 42 | - | - | - | - | - | - | - | - |
$230 8,792 kWh |
$430 42 kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $260 Cost: $100 |
$260 | 9,965 | - | - | - | - | - | - | - | - | - | - |
$260 9,965 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $120 Cost: - |
$180 | 6,448 | - | - | - | - | - | - | - | - | $(-60) | - |
$180 6,448 kWh |
- - kW-months/year |
- - MMBtu |
- - gal |
- - lb |
$(-60) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $8,955 Cost: $4,928 |
$1,230 | 47,186 | $1,600 | 154 | $4,070 | 1,566 | $875 | 467 | $930 | 13,230 | $250 | - | $1,230 47,186 kWh |
$1,600 154 kW-months/year |
$4,070 1,566 MMBtu |
$875 467 gal |
$930 13,230 lb |
$250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,150 Cost: $3,698 |
$1,230 | 47,186 | $1,600 | 154 | $4,070 | 1,566 | - | - | - | - | $250 | - | $1,230 47,186 kWh |
$1,600 154 kW-months/year |
$4,070 1,566 MMBtu |
- - gal |
- - lb |
$250 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | gal | $ | lb | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Liquid (haz) | Solid Waste (non-haz) | Personnel Changes |