Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2002 |
Principal Product | Corrugated Boxes |
NAICS | n/a |
SIC | 2653 - Corrugated And Solid Fiber Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 80 |
Plant Area (Sq.Ft.) | 175,000 |
Annual Production | 660,000 Thousand Feet |
Production Hrs. Annual | 6,096 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $291,780 | 4,713,427 | kWh | $0.06 |
Electricity Demand | $82,952 | 13,230 | kW-months/year | $6.27 |
Natural Gas | $201,584 | 33,596 | MMBtu | $6.00 |
TOTAL ENERGY COSTS | $576,316 | |||
RECOMMENDED SAVINGS* | $199,860 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $199,480 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $120,900 Cost: $8,000 |
- | - | - | - | - | - | - | - | $120,900 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$120,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $32,450 Cost: $24,980 |
- | - | $32,450 | 2,636 | - | - | - | - | - | - |
- - kWh |
$32,450 2,636 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $32,210 Cost: $4,900 |
- | - | - | - | $32,210 | 5,137 | - | - | - | - |
- - kWh |
- - kW-months/year |
$32,210 5,137 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,230 Cost: $1,330 |
- | - | - | - | $7,230 | 1,170 | - | - | - | - |
- - kWh |
- - kW-months/year |
$7,230 1,170 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2113 REPAIR OR REPLACE STEAM TRAPS |
Savings: $3,480 Cost: $450 |
- | - | - | - | $3,480 | 563 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,480 563 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,670 Cost: $880 |
$1,670 | 38,830 | - | - | - | - | - | - | - | - |
$1,670 38,830 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,100 Cost: $780 |
$315 | 7,320 | $120 | 10 | - | - | $665 | - | - | - |
$315 7,320 kWh |
$120 10 kW-months/year |
- - MMBtu |
$665 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $440 Cost: - |
$440 | 10,230 | - | - | - | - | - | - | - | - |
$440 10,230 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $380 Cost: - |
$330 | 7,630 | $50 | 4 | - | - | - | - | - | - |
$330 7,630 kWh |
$50 4 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $199,860 Cost: $41,320 |
$2,755 | 64,010 | $32,620 | 2,650 | $42,920 | 6,870 | $665 | - | $120,900 | - | $2,755 64,010 kWh |
$32,620 2,650 kW-months/year |
$42,920 6,870 MMBtu |
$665 - $ |
$120,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $199,480 Cost: $41,320 |
$2,425 | 56,380 | $32,570 | 2,646 | $42,920 | 6,870 | $665 | - | $120,900 | - | $2,425 56,380 kWh |
$32,570 2,646 kW-months/year |
$42,920 6,870 MMBtu |
$665 - $ |
$120,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |