Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2004 |
Principal Product | Oil field equipment |
NAICS | 333132 - Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 110,000 |
Annual Production | 10,560 Pieces |
Production Hrs. Annual | 7,224 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $547,573 | 8,773,100 | kWh | $0.06 |
Electricity Demand | $105,689 | 14,399 | kW-months/year | $7.34 |
Electricity Fees | $4,381 | - | $ | - |
Natural Gas | $135,965 | 18,877 | MMBtu | $7.20 |
TOTAL ENERGY COSTS | $793,608 | |||
RECOMMENDED SAVINGS* | $76,760 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $66,890 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7425 CLEAN OR COLOR ROOF TO REDUCE SOLAR LOAD |
Savings: $28,350 Cost: $136,800 |
$28,350 | 667,000 | - | - | - | - | - | - | - | - |
$28,350 667,000 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,500 Cost: $500 |
- | - | - | - | $5,500 | 765 | - | - | - | - |
- - kWh |
- - kW-months/year |
$5,500 765 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,200 Cost: $500 |
$5,200 | 122,000 | - | - | - | - | - | - | - | - |
$5,200 122,000 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $3,490 Cost: $70 |
- | - | - | - | $3,490 | 484 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,490 484 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $1,930 Cost: - |
$1,520 | 35,750 | $410 | 60 | - | - | - | - | - | - |
$1,520 35,750 kWh |
$410 60 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,840 Cost: $770 |
$200 | 4,900 | $50 | 7 | - | - | $1,590 | - | - | - |
$200 4,900 kWh |
$50 7 kW-months/year |
- - MMBtu |
$1,590 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $550 Cost: $175 |
$550 | 13,000 | - | - | - | - | - | - | - | - |
$550 13,000 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $26,000 Cost: $18,000 |
- | - | - | - | - | - | - | - | $26,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$26,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED |
Savings: $3,900 Cost: - |
- | - | - | - | - | - | - | - | $3,900 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$3,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $76,760 Cost: $156,815 |
$35,820 | 842,650 | $460 | 67 | $8,990 | 1,249 | $1,590 | - | $29,900 | - | $35,820 842,650 kWh |
$460 67 kW-months/year |
$8,990 1,249 MMBtu |
$1,590 - $ |
$29,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $66,890 Cost: $156,570 |
$33,750 | 793,900 | $50 | 7 | $5,500 | 765 | $1,590 | - | $26,000 | - | $33,750 793,900 kWh |
$50 7 kW-months/year |
$5,500 765 MMBtu |
$1,590 - $ |
$26,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes |