Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2005 |
Principal Product | Paperboard packaging |
NAICS | 322130 - Paperboard Mills |
SIC | 2657 - Folding Paperboard Boxes |
Sales | $10,000,000-$50,000,000 |
# of Employees | 160 |
Plant Area (Sq.Ft.) | 191,000 |
Annual Production | 24,000 Tons |
Production Hrs. Annual | 6,024 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $536,147 | 9,966,140 | kWh | $0.05 |
Electricity Demand | $114,914 | 21,422 | kW-months/year | $5.36 |
Electricity Fees | $500 | - | $ | - |
Natural Gas | $27,691 | 3,192 | MMBtu | $8.68 |
TOTAL ENERGY COSTS | $679,252 | |||
RECOMMENDED SAVINGS* | $173,020 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM |
Savings: $108,000 Cost: $24,500 |
$93,000 | 1,607,000 | $13,000 | 2,300 | - | - | $2,000 | - | - | - |
$93,000 1,607,000 kWh |
$13,000 2,300 kW-months/year |
- - $ |
$2,000 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $27,000 Cost: $61,600 |
- | - | $27,000 | 4,700 | - | - | - | - | - | - |
- - kWh |
$27,000 4,700 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $13,460 Cost: $500 |
$11,800 | 203,200 | $1,660 | 286 | - | - | - | - | - | - |
$11,800 203,200 kWh |
$1,660 286 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $10,400 Cost: $1,200 |
$6,500 | 112,000 | $3,900 | 671 | - | - | - | - | - | - |
$6,500 112,000 kWh |
$3,900 671 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $2,600 Cost: $100 |
$2,300 | 40,400 | $300 | 58 | - | - | - | - | - | - |
$2,300 40,400 kWh |
$300 58 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,700 Cost: $2,100 |
$1,500 | 25,700 | $200 | 40 | - | - | - | - | - | - |
$1,500 25,700 kWh |
$200 40 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $920 Cost: $500 |
$160 | 2,700 | $20 | 4 | $740 | - | - | - | - | - |
$160 2,700 kWh |
$20 4 kW-months/year |
$740 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $8,940 Cost: $4,200 |
- | - | - | - | - | - | $540 | - | $8,400 | - |
- - kWh |
- - kW-months/year |
- - $ |
$540 - $ |
$8,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $173,020 Cost: $94,700 |
$115,260 | 1,991,000 | $46,080 | 8,059 | $740 | - | $2,540 | - | $8,400 | - | $115,260 1,991,000 kWh |
$46,080 8,059 kW-months/year |
$740 - $ |
$2,540 - $ |
$8,400 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | One-time Revenue or Avoided Cost |