Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2005 |
Principal Product | Newspapers |
NAICS | 323111 - Commercial Printing (except Screen and Books) |
SIC | 2711 - Newspapers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 257 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 27,000,000 Pieces |
Production Hrs. Annual | 2,028 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $153,387 | 2,691,000 | kWh | $0.06 |
Electricity Demand | $44,629 | 6,739 | kW-months/year | $6.62 |
Natural Gas | $1,838 | 159 | MMBtu | $11.56 |
TOTAL ENERGY COSTS | $199,854 | |||
RECOMMENDED SAVINGS* | $18,314 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,590 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $6,000 Cost: $5,250 |
- | - | $6,000 | 816 | - | - | - | - | - | - |
- - kWh |
$6,000 816 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,898 Cost: - |
$2,470 | 43,400 | $435 | 59 | - | - | $993 | - | - | - |
$2,470 43,400 kWh |
$435 59 kW-months/year |
- - $ |
$993 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,255 Cost: $15 |
$1,920 | 33,700 | $335 | 46 | - | - | - | - | - | - |
$1,920 33,700 kWh |
$335 46 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED |
Savings: $1,580 Cost: - |
- | - | - | - | - | - | $1,580 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,580 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,480 Cost: $770 |
$280 | 4,900 | $50 | 7 | - | - | $1,150 | - | - | - |
$280 4,900 kWh |
$50 7 kW-months/year |
- - $ |
$1,150 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $975 Cost: $150 |
$830 | 14,500 | $145 | 20 | - | - | - | - | - | - |
$830 14,500 kWh |
$145 20 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $830 Cost: $165 |
$830 | 14,650 | - | - | - | - | - | - | - | - |
$830 14,650 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $596 Cost: - |
$384 | 6,730 | $212 | 29 | - | - | - | - | - | - |
$384 6,730 kWh |
$212 29 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $700 Cost: $280 |
- | - | - | - | $140 | - | - | - | $560 | - |
- - kWh |
- - kW-months/year |
$140 - $ |
- - $ |
$560 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,314 Cost: $6,630 |
$6,714 | 117,880 | $7,177 | 977 | $140 | - | $3,723 | - | $560 | - | $6,714 117,880 kWh |
$7,177 977 kW-months/year |
$140 - $ |
$3,723 - $ |
$560 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,590 Cost: $1,215 |
$1,110 | 19,550 | $50 | 7 | $140 | - | $2,730 | - | $560 | - | $1,110 19,550 kWh |
$50 7 kW-months/year |
$140 - $ |
$2,730 - $ |
$560 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |