Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2006
Principal Product Newspapers
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2711 - Newspapers
Sales $100,000,000-$500,000,000
# of Employees 850
Plant Area (Sq.Ft.) 448,000
Annual Production 240,000,000 Pieces
Production Hrs. Annual 7,800
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $955,949 21,891,980 kWh $0.04
Electricity Demand $352,570 53,644 kW-months/year $6.57
Electricity Fees $50,867 - $ -
Natural Gas $189,805 17,400 MMBtu $10.91
TOTAL ENERGY COSTS $1,549,191
RECOMMENDED SAVINGS* $69,470 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $53,630
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Disposal Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Water Disposal Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$44,220
Cost:
$1,000
- - - - $44,220 4,330 - - - - -
-
kWh
-
-
kW-months/year
$44,220
4,330
MMBtu
-
-
Tgal
-
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$15,840
Cost:
$2,500
$15,840 386,230 - - - - - - - - $15,840
386,230
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
03: 3.4154 ELIMINATE LEAKS IN WATER LINES AND VALVES Savings:
$4,000
Cost:
$415
- - - - - - $4,000 1,051,200 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,000
1,051,200
Tgal
-
-
$
04: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED Savings:
$3,850
Cost:
-
- - - - - - - - $3,850 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
$3,850
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,280
Cost:
$500
$975 23,900 $305 37 - - - - - - $975
23,900
kWh
$305
37
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$280
Cost:
-
$220 5,400 $60 7 - - - - - - $220
5,400
kWh
$60
7
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
TOTAL RECOMMENDED Savings:
$69,470
Cost:
$4,415
$17,035 415,530 $365 44 $44,220 4,330 $4,000 1,051,200 $3,850 - $17,035
415,530
kWh
$365
44
kW-months/year
$44,220
4,330
MMBtu
$4,000
1,051,200
Tgal
$3,850
-
$
TOTAL IMPLEMENTED Savings:
$53,630
Cost:
$1,915
$1,195 29,300 $365 44 $44,220 4,330 $4,000 1,051,200 $3,850 - $1,195
29,300
kWh
$365
44
kW-months/year
$44,220
4,330
MMBtu
$4,000
1,051,200
Tgal
$3,850
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Disposal Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Water Disposal Ancillary Material Cost