Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2008 |
Principal Product | Heat Treating |
NAICS | 332811 - Metal Heat Treating |
SIC | 3398 - Metal Heat Treating |
Sales | $10,000,000-$50,000,000 |
# of Employees | 40 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 20,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $460,652 | 5,483,948 | kWh | $0.08 |
Electricity Demand | $110,321 | 15,408 | kW-months/year | $7.16 |
Electricity Fees | $28,000 | - | $ | - |
Natural Gas | $855,000 | 112,000 | MMBtu | $7.63 |
TOTAL ENERGY COSTS | $1,453,973 | |||
RECOMMENDED SAVINGS* | $99,171 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $95,832 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $95,000 Cost: $175,000 |
- | - | - | - | $95,000 | 12,500 | - | - | - | - |
- - kWh |
- - kW-months/year |
$95,000 12,500 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7145 INSTALL SKYLIGHTS |
Savings: $3,050 Cost: $1,760 |
$3,300 | 39,400 | - | - | - | - | $(-250) | - | - | - |
$3,300 39,400 kWh |
- - kW-months/year |
- - MMBtu |
$(-250) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $627 Cost: - |
$268 | 3,190 | $31 | 4 | - | - | - | - | $328 | - |
$268 3,190 kWh |
$31 4 kW-months/year |
- - MMBtu |
- - $ |
$328 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $205 Cost: $54 |
$164 | 1,950 | $41 | 6 | - | - | - | - | - | - |
$164 1,950 kWh |
$41 6 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5113 SELL OIL TO RECYCLER |
Savings: $289 Cost: $837 |
- | - | - | - | - | - | - | - | $289 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$289 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $99,171 Cost: $177,651 |
$3,732 | 44,540 | $72 | 10 | $95,000 | 12,500 | $(-250) | - | $617 | - | $3,732 44,540 kWh |
$72 10 kW-months/year |
$95,000 12,500 MMBtu |
$(-250) - $ |
$617 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $95,832 Cost: $175,054 |
$432 | 5,140 | $72 | 10 | $95,000 | 12,500 | - | - | $328 | - | $432 5,140 kWh |
$72 10 kW-months/year |
$95,000 12,500 MMBtu |
- - $ |
$328 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Ancillary Material Cost |