Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2010 |
Principal Product | Insulated glass window units |
NAICS | 327211 - Flat Glass Manufacturing |
SIC | 3211 - Flat Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 89 |
Plant Area (Sq.Ft.) | 180,000 |
Annual Production | 450,000 Pieces |
Production Hrs. Annual | 2,500 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $775,864 | 8,455,934 | kWh | $0.09 |
Electricity Demand | $199,534 | 29,397 | kW-months/year | $6.79 |
Electricity Fees | $22,931 | - | $ | - |
Natural Gas | $71,500 | 14,928 | MMBtu | $4.79 |
TOTAL ENERGY COSTS | $1,069,829 | |||
RECOMMENDED SAVINGS* | $46,280 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,550 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.451 ADD ADDITIONAL PRODUCTION SHIFT |
Savings: $18,420 Cost: - |
$(-8,550) | (-95,000) | $38,220 | 6,000 | - | - | - | - | $(-11,250) | - | - | - |
$(-8,550) (-95,000) kWh |
$38,220 6,000 kW-months/year |
- - $ |
- - lb |
$(-11,250) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $17,800 Cost: $3,915 |
$12,400 | 137,650 | $4,200 | 657 | - | - | - | - | - | - | $1,200 | - |
$12,400 137,650 kWh |
$4,200 657 kW-months/year |
- - $ |
- - lb |
- - $ |
$1,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,360 Cost: $500 |
$4,000 | 44,390 | $1,360 | 213 | - | - | - | - | - | - | - | - |
$4,000 44,390 kWh |
$1,360 213 kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,750 Cost: $685 |
$390 | 4,350 | $40 | 6 | - | - | - | - | $1,320 | - | - | - |
$390 4,350 kWh |
$40 6 kW-months/year |
- - $ |
- - lb |
$1,320 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS |
Savings: $1,370 Cost: - |
- | - | - | - | - | - | $1,370 | 13,700 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$1,370 13,700 lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8112 COMBINE UTILITY METERS |
Savings: $1,310 Cost: $1,250 |
- | - | $810 | 127 | $500 | - | - | - | - | - | - | - |
- - kWh |
$810 127 kW-months/year |
$500 - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $270 Cost: $105 |
$225 | 2,500 | $45 | 7 | - | - | - | - | - | - | - | - |
$225 2,500 kWh |
$45 7 kW-months/year |
- - $ |
- - lb |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,280 Cost: $6,455 |
$8,465 | 93,890 | $44,675 | 7,010 | $500 | - | $1,370 | 13,700 | $(-9,930) | - | $1,200 | - | $8,465 93,890 kWh |
$44,675 7,010 kW-months/year |
$500 - $ |
$1,370 13,700 lb |
$(-9,930) - $ |
$1,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,550 Cost: $5,205 |
$17,015 | 188,890 | $5,645 | 883 | - | - | $1,370 | 13,700 | $1,320 | - | $1,200 | - | $17,015 188,890 kWh |
$5,645 883 kW-months/year |
- - $ |
$1,370 13,700 lb |
$1,320 - $ |
$1,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Electricity Fees | Solid Waste (haz) | Personnel Changes | Ancillary Material Cost |