Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2011 |
Principal Product | Refurbished Blow-Out Preventers |
NAICS | 333132 - Oil and Gas Field Machinery and Equipment Manufacturing |
SIC | 3533 - Oil And Gas Field Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 61 |
Plant Area (Sq.Ft.) | 57,000 |
Annual Production | 800 Pieces |
Production Hrs. Annual | 7,440 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $117,110 | 2,015,763 | kWh | $0.06 |
Electricity Demand | $47,134 | 7,958 | kW-months/year | $5.92 |
Electricity Fees | $9,872 | - | $ | - |
Natural Gas | $52,346 | 5,395 | MMBtu | $9.70 |
TOTAL ENERGY COSTS | $226,462 | |||
RECOMMENDED SAVINGS* | $104,415 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $59,215 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.4151 MINIMIZE WATER USAGE |
Savings: $36,500 Cost: $20,000 |
- | - | - | - | $(-2,170) | (-190) | $38,670 | 22,200 | - | - |
- - kWh |
- - kW-months/year |
$(-2,170) (-190) MMBtu |
$38,670 22,200 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,200 Cost: $11,140 |
$21,000 | 357,000 | $5,200 | 707 | - | - | - | - | - | - |
$21,000 357,000 kWh |
$5,200 707 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5314 USE IN-PROCESS RECYCLING WHENEVER POSSIBLE |
Savings: $17,240 Cost: - |
- | - | - | - | - | - | - | - | $17,240 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$17,240 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $8,700 Cost: - |
- | - | - | - | - | - | - | - | $8,700 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$8,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $6,100 Cost: $14,200 |
- | - | $6,100 | 826 | - | - | - | - | - | - |
- - kWh |
$6,100 826 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7145 INSTALL SKYLIGHTS |
Savings: $5,600 Cost: $100 |
$5,600 | 98,200 | - | - | - | - | - | - | - | - |
$5,600 98,200 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,770 Cost: $500 |
$3,010 | 52,000 | $760 | 103 | - | - | - | - | - | - |
$3,010 52,000 kWh |
$760 103 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $195 Cost: $600 |
$195 | 3,140 | - | - | - | - | - | - | - | - |
$195 3,140 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $110 Cost: - |
$110 | 1,900 | - | - | - | - | - | - | - | - |
$110 1,900 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $104,415 Cost: $46,540 |
$29,915 | 512,240 | $12,060 | 1,636 | $(-2,170) | (-190) | $38,670 | 22,200 | $25,940 | - | $29,915 512,240 kWh |
$12,060 1,636 kW-months/year |
$(-2,170) (-190) MMBtu |
$38,670 22,200 Tgal |
$25,940 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $59,215 Cost: $26,540 |
$29,915 | 512,240 | $12,060 | 1,636 | - | - | - | - | $17,240 | - | $29,915 512,240 kWh |
$12,060 1,636 kW-months/year |
- - MMBtu |
- - Tgal |
$17,240 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Ancillary Material Cost |