Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2012 |
Principal Product | Kitchen and bathroom cabinets |
NAICS | 337110 - Wood Kitchen Cabinet and Countertop Manufacturing |
SIC | 2434 - Wood Kitchen Cabinets |
Sales | $10,000,000-$50,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 200,000 |
Annual Production | 60,000 Pieces |
Production Hrs. Annual | 1,992 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $168,789 | 2,432,130 | kWh | $0.07 |
Electricity Demand | $94,885 | 12,010 | kW-months/year | $7.90 |
Electricity Fees | $35,915 | - | $ | - |
Natural Gas | $1,736 | 225 | MMBtu | $7.72 |
TOTAL ENERGY COSTS | $301,325 | |||
RECOMMENDED SAVINGS* | $181,270 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $180,440 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $42,700 Cost: $60,200 |
- | - | $42,700 | 5,400 | - | - | - | - | - | - |
- - kWh |
$42,700 5,400 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $109,000 Cost: $10,900 |
- | - | - | - | $21,800 | - | - | - | $87,200 | - |
- - kWh |
- - kW-months/year |
$21,800 - $ |
- - $ |
$87,200 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.8123 PAY UTILITY BILLS ON TIME |
Savings: $9,700 Cost: - |
- | - | - | - | $9,700 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$9,700 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,300 Cost: $17,365 |
$2,560 | 36,600 | $1,740 | 221 | - | - | - | - | - | - |
$2,560 36,600 kWh |
$1,740 221 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,510 Cost: $620 |
$1,480 | 21,220 | $1,030 | 130 | - | - | - | - | - | - |
$1,480 21,220 kWh |
$1,030 130 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $12,130 Cost: $1,200 |
- | - | - | - | $2,430 | - | - | - | $9,700 | - |
- - kWh |
- - kW-months/year |
$2,430 - $ |
- - $ |
$9,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $830 Cost: $500 |
$190 | 2,660 | $30 | 4 | - | - | $610 | - | - | - |
$190 2,660 kWh |
$30 4 kW-months/year |
- - $ |
$610 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $100 Cost: - |
$60 | 890 | $40 | 5 | - | - | - | - | - | - |
$60 890 kWh |
$40 5 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $181,270 Cost: $90,785 |
$4,290 | 61,370 | $45,540 | 5,760 | $33,930 | - | $610 | - | $96,900 | - | $4,290 61,370 kWh |
$45,540 5,760 kW-months/year |
$33,930 - $ |
$610 - $ |
$96,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $180,440 Cost: $90,285 |
$4,100 | 58,710 | $45,510 | 5,756 | $33,930 | - | - | - | $96,900 | - | $4,100 58,710 kWh |
$45,510 5,756 kW-months/year |
$33,930 - $ |
- - $ |
$96,900 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | One-time Revenue or Avoided Cost |