Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2013 |
Principal Product | Pumps |
NAICS | 333911 - Pump and Pumping Equipment Manufacturing |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $10,000,000-$50,000,000 |
# of Employees | 55 |
Plant Area (Sq.Ft.) | 34,200 |
Annual Production | 500 Pieces |
Production Hrs. Annual | 2,685 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $39,023 | 578,604 | kWh | $0.07 |
Electricity Demand | $22,651 | 2,849 | kW-months/year | $7.95 |
Electricity Fees | $5,748 | - | $ | - |
TOTAL ENERGY COSTS | $67,423 | |||
RECOMMENDED SAVINGS* | $49,474 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $37,073 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $28,740 Cost: $5,000 |
- | - | - | - | $5,748 | - | - | - | - | - | $22,992 | - |
- - kWh |
- - kW-months/year |
$5,748 - $ |
- - $ |
- - $ |
$22,992 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,979 Cost: $8,431 |
$6,554 | 96,383 | $3,425 | 431 | - | - | - | - | - | - | - | - |
$6,554 96,383 kWh |
$3,425 431 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,536 Cost: $1,460 |
$4,952 | 72,817 | $2,584 | 325 | - | - | - | - | - | - | - | - |
$4,952 72,817 kWh |
$2,584 325 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $1,130 Cost: $666 |
$1,130 | 16,622 | - | - | - | - | - | - | - | - | - | - |
$1,130 16,622 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $850 Cost: $177 |
$850 | 12,540 | - | - | - | - | - | - | - | - | - | - |
$850 12,540 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $485 Cost: - |
$313 | 4,602 | $172 | 22 | - | - | - | - | - | - | - | - |
$313 4,602 kWh |
$172 22 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $312 Cost: $505 |
$312 | 4,610 | - | - | - | - | - | - | - | - | - | - |
$312 4,610 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $250 Cost: - |
$165 | 2,430 | $85 | 11 | - | - | - | - | - | - | - | - |
$165 2,430 kWh |
$85 11 kW-months/year |
- - $ |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $192 Cost: $95 |
$34 | 501 | $6 | 1 | - | - | $72 | - | $80 | - | - | - |
$34 501 kWh |
$6 1 kW-months/year |
- - $ |
$72 - $ |
$80 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,474 Cost: $16,334 |
$14,310 | 210,505 | $6,272 | 789 | $5,748 | - | $72 | - | $80 | - | $22,992 | - | $14,310 210,505 kWh |
$6,272 789 kW-months/year |
$5,748 - $ |
$72 - $ |
$80 - $ |
$22,992 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $37,073 Cost: $6,965 |
$5,577 | 82,029 | $2,756 | 347 | $5,748 | - | - | - | - | - | $22,992 | - | $5,577 82,029 kWh |
$2,756 347 kW-months/year |
$5,748 - $ |
- - $ |
- - $ |
$22,992 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Personnel Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |