Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2017 |
Principal Product | Reflective glass beads |
NAICS | 327215 - Glass Product Manufacturing Made of Purchased Glass |
SIC | 3231 - Products Of Purchased Glass |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 80,000 |
Annual Production | 80,000 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $581,745 | 12,137,390 | kWh | $0.05 |
Electricity Demand | $101,200 | 23,109 | kW-months/year | $4.38 |
Electricity Fees | $9,914 | - | $ | - |
Natural Gas | $1,674,197 | 448,976 | MMBtu | $3.73 |
TOTAL ENERGY COSTS | $2,367,056 | |||
RECOMMENDED SAVINGS* | $120,450 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $120,450 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $79,400 Cost: $262,500 |
- | - | $9,400 | 1,150 | - | - | - | - | $70,000 | - |
- - kWh |
$9,400 1,150 kW-months/year |
- - $ |
- - $ |
$70,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $27,250 Cost: $15,000 |
- | - | - | - | $5,450 | - | $21,800 | - | - | - |
- - kWh |
- - kW-months/year |
$5,450 - $ |
$21,800 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $4,880 Cost: $1,000 |
$3,960 | 82,600 | $920 | 113 | - | - | - | - | - | - |
$3,960 82,600 kWh |
$920 113 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,640 Cost: $13,720 |
$4,170 | 87,200 | $1,470 | 181 | - | - | - | - | - | - |
$4,170 87,200 kWh |
$1,470 181 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,890 Cost: $2,060 |
$1,530 | 32,100 | $360 | 44 | - | - | - | - | - | - |
$1,530 32,100 kWh |
$360 44 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $730 Cost: - |
$430 | 9,000 | $300 | 37 | - | - | - | - | - | - |
$430 9,000 kWh |
$300 37 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $350 Cost: $270 |
$350 | 7,400 | - | - | - | - | - | - | - | - |
$350 7,400 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $310 Cost: $130 |
$310 | 6,440 | - | - | - | - | - | - | - | - |
$310 6,440 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,450 Cost: $294,680 |
$10,750 | 224,740 | $12,450 | 1,525 | $5,450 | - | $21,800 | - | $70,000 | - | $10,750 224,740 kWh |
$12,450 1,525 kW-months/year |
$5,450 - $ |
$21,800 - $ |
$70,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $120,450 Cost: $294,680 |
$10,750 | 224,740 | $12,450 | 1,525 | $5,450 | - | $21,800 | - | $70,000 | - | $10,750 224,740 kWh |
$12,450 1,525 kW-months/year |
$5,450 - $ |
$21,800 - $ |
$70,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Primary Product |