Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2017 |
Principal Product | Trenchers |
NAICS | 333923 - Overhead Traveling Crane, Hoist, and Monorail System Manufacturing |
SIC | 3531 - Construction Machinery |
Sales | $10,000,000-$50,000,000 |
# of Employees | 66 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 12 Units |
Production Hrs. Annual | 2,500 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $51,946 | 1,206,100 | kWh | $0.04 |
Electricity Demand | $54,190 | 5,412 | kW-months/year | $10.01 |
Electricity Fees | $667 | - | $ | - |
LPG | $8,493 | 425 | MMBtu | $19.98 |
TOTAL ENERGY COSTS | $115,296 | |||
RECOMMENDED SAVINGS* | $33,600 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $24,165 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $18,250 Cost: $52,360 |
$9,450 | 210,000 | $8,800 | 917 | - | - | - | - |
$9,450 210,000 kWh |
$8,800 917 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $8,320 Cost: $4,120 |
- | - | - | - | - | - | $8,320 | - |
- - kWh |
- - kW-months/year |
- - $ |
$8,320 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $2,770 Cost: $320 |
$1,630 | 36,200 | $1,140 | 119 | - | - | - | - |
$1,630 36,200 kWh |
$1,140 119 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $920 Cost: $1,700 |
$920 | 20,500 | - | - | - | - | - | - |
$920 20,500 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.7132 REUSE RAGS UNTIL COMPLETELY SOILED |
Savings: $880 Cost: - |
- | - | - | - | - | - | $880 | - |
- - kWh |
- - kW-months/year |
- - $ |
$880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,160 Cost: $500 |
$575 | 12,800 | $585 | 61 | - | - | - | - |
$575 12,800 kWh |
$585 61 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,105 Cost: $410 |
$95 | 2,145 | $25 | 3 | $985 | - | - | - |
$95 2,145 kWh |
$25 3 kW-months/year |
$985 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $195 Cost: $15 |
$95 | 2,100 | $100 | 10 | - | - | - | - |
$95 2,100 kWh |
$100 10 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $33,600 Cost: $59,425 |
$12,765 | 283,745 | $10,650 | 1,110 | $985 | - | $9,200 | - | $12,765 283,745 kWh |
$10,650 1,110 kW-months/year |
$985 - $ |
$9,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $24,165 Cost: $53,590 |
$11,750 | 261,145 | $10,550 | 1,100 | $985 | - | $880 | - | $11,750 261,145 kWh |
$10,550 1,100 kW-months/year |
$985 - $ |
$880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |