Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2018 |
Principal Product | Beef and pork processing |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | $100,000,000-$500,000,000 |
# of Employees | 480 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 32,000,000 Pounds |
Production Hrs. Annual | 8,640 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $914,832 | 19,848,000 | kWh | $0.05 |
Electricity Demand | $414,924 | 45,089 | kW-months/year | $9.20 |
Electricity Fees | $38,502 | - | $ | - |
Natural Gas | $184,950 | 50,376 | MMBtu | $3.67 |
TOTAL ENERGY COSTS | $1,553,208 | |||
RECOMMENDED SAVINGS* | $273,385 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL |
Savings: $136,440 Cost: $167,100 |
$107,400 | 2,619,400 | $29,040 | 3,590 | - | - | - | - | - | - |
$107,400 2,619,400 kWh |
$29,040 3,590 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8112 COMBINE UTILITY METERS |
Savings: $65,915 Cost: $10,000 |
- | - | $65,915 | 7,339 | - | - | - | - | - | - |
- - kWh |
$65,915 7,339 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $31,797 Cost: $45,252 |
- | - | $31,797 | 3,537 | - | - | - | - | - | - |
- - kWh |
$31,797 3,537 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $17,000 Cost: $15,400 |
$11,495 | 280,430 | $5,505 | 490 | - | - | - | - | - | - |
$11,495 280,430 kWh |
$5,505 490 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $6,165 Cost: $40 |
$4,200 | 102,460 | $1,965 | 175 | - | - | - | - | - | - |
$4,200 102,460 kWh |
$1,965 175 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $9,336 Cost: $1,560 |
$3,073 | 74,994 | - | - | - | - | $1,017 | - | $5,246 | - |
$3,073 74,994 kWh |
- - kW-months/year |
- - $ |
$1,017 - $ |
$5,246 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,109 Cost: $5,410 |
$2,180 | 53,180 | $436 | 45 | $(-349) | - | - | - | $3,842 | - |
$2,180 53,180 kWh |
$436 45 kW-months/year |
$(-349) - $ |
- - $ |
$3,842 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $623 Cost: $140 |
$375 | 9,140 | $124 | 12 | $124 | - | - | - | - | - |
$375 9,140 kWh |
$124 12 kW-months/year |
$124 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $273,385 Cost: $244,902 |
$128,723 | 3,139,604 | $134,782 | 15,188 | $(-225) | - | $1,017 | - | $9,088 | - | $128,723 3,139,604 kWh |
$134,782 15,188 kW-months/year |
$(-225) - $ |
$1,017 - $ |
$9,088 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |