Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Texas A&M, College Station |
---|---|
Assessment Year | 2020 |
Principal Product | Aluminum beverage cans |
NAICS | 332431 - Metal Can Manufacturing |
SIC | 3411 - Metal Cans |
Sales | $100,000,000-$500,000,000 |
# of Employees | 163 |
Plant Area (Sq.Ft.) | 350,000 |
Annual Production | 2,000,000,000 Pieces |
Production Hrs. Annual | 8,688 |
Location (State) | TX |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,460,363 | 45,636,370 | kWh | $0.03 |
Electricity Demand | $880,560 | 90,967 | kW-months/year | $9.68 |
Electricity Fees | $160,182 | - | $ | - |
Natural Gas | $380,043 | 106,305 | MMBtu | $3.58 |
TOTAL ENERGY COSTS | $2,881,148 | |||
RECOMMENDED SAVINGS* | $579,660 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $535,860 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $336,600 Cost: - |
- | - | - | - | $168,300 | - | $168,300 | - |
- - kWh |
- - kW-months/year |
$168,300 - $ |
$168,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $126,730 Cost: $229,415 |
- | - | $126,730 | 13,092 | - | - | - | - |
- - kWh |
$126,730 13,092 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $66,000 Cost: $20,000 |
$44,080 | 1,377,000 | $21,920 | 2,265 | - | - | - | - |
$44,080 1,377,000 kWh |
$21,920 2,265 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $31,045 Cost: $150 |
$20,735 | 648,000 | $10,310 | 1,065 | - | - | - | - |
$20,735 648,000 kWh |
$10,310 1,065 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $10,800 Cost: $4,680 |
$7,200 | 226,000 | $3,600 | 370 | - | - | - | - |
$7,200 226,000 kWh |
$3,600 370 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,120 Cost: $11,560 |
$3,420 | 107,000 | $1,700 | 176 | - | - | - | - |
$3,420 107,000 kWh |
$1,700 176 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $1,955 Cost: - |
- | - | $1,955 | 202 | - | - | - | - |
- - kWh |
$1,955 202 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,410 Cost: $1,570 |
$710 | 22,130 | $700 | 72 | - | - | - | - |
$710 22,130 kWh |
$700 72 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $579,660 Cost: $267,375 |
$76,145 | 2,380,130 | $166,915 | 17,242 | $168,300 | - | $168,300 | - | $76,145 2,380,130 kWh |
$166,915 17,242 kW-months/year |
$168,300 - $ |
$168,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $535,860 Cost: $262,545 |
$48,210 | 1,506,130 | $151,050 | 15,605 | $168,300 | - | $168,300 | - | $48,210 1,506,130 kWh |
$151,050 15,605 kW-months/year |
$168,300 - $ |
$168,300 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | One-time Revenue or Avoided Cost |