IAC logo
IAC Assessment: AM0810
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0810
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2020
Principal Product wood fiber products
NAICS 321912 - Cut Stock, Resawing Lumber, and Planing
SIC 2421 - Sawmills And Planing Mills, General
Sales $10,000,000-$50,000,000
# of Employees 30
Plant Area (Sq.Ft.) 52,500
Annual Production 66,000 Thousand Feet
Production Hrs. Annual 2,224
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $34,050 587,310 kWh $0.06
Electricity Demand $35,780 4,924 kW-months/year $7.27
Electricity Fees $(-234) - $ -
TOTAL ENERGY COSTS $69,596
RECOMMENDED SAVINGS* $14,835 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,835
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost
$ kWh $ kW-months/year $ $
01: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS Savings:
$5,200
Cost:
$1,000
- - - - $5,200 - -
-
kWh
-
-
kW-months/year
$5,200
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,320
Cost:
$1,680
$2,020 34,800 $1,300 177 - - $2,020
34,800
kWh
$1,300
177
kW-months/year
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,410
Cost:
$180
$3,410 58,830 - - - - $3,410
58,830
kWh
-
-
kW-months/year
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,245
Cost:
$2,670
$1,045 18,050 $1,200 162 - - $1,045
18,050
kWh
$1,200
162
kW-months/year
-
-
$
05: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$370
Cost:
$50
- - - - $370 - -
-
kWh
-
-
kW-months/year
$370
-
$
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$290
Cost:
$20
$160 2,825 $130 18 - - $160
2,825
kWh
$130
18
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$14,835
Cost:
$5,600
$6,635 114,505 $2,630 357 $5,570 - $6,635
114,505
kWh
$2,630
357
kW-months/year
$5,570
-
$
TOTAL IMPLEMENTED Savings:
$14,835
Cost:
$5,600
$6,635 114,505 $2,630 357 $5,570 - $6,635
114,505
kWh
$2,630
357
kW-months/year
$5,570
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost