IAC logo
IAC Assessment: AM0842
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0842
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2022
Principal Product Treated Waste Water
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $1,000,000-$5,000,000
# of Employees 4
Plant Area (Sq.Ft.) 484,000
Annual Production 1,300 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $71,760 1,823,402 kWh $0.04
Electricity Demand $54,227 4,210 kW-months/year $12.88
TOTAL ENERGY COSTS $125,987
RECOMMENDED SAVINGS* $5,393 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $5,283
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.4156 ESTABLISH A PREVENTATIVE MAINTENANCE PROGRAM Savings:
$4,317
Cost:
$4,220
$4,047 103,766 - - - - $270 - $4,047
103,766
kWh
-
-
kW-months/year
-
-
$
$270
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$966
Cost:
$3,411
$1,132 29,038 - - - - $(-166) - $1,132
29,038
kWh
-
-
kW-months/year
-
-
$
$(-166)
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$110
Cost:
$37
$9 237 $5 0 $64 - $32 - $9
237
kWh
$5
0
kW-months/year
$64
-
$
$32
-
$
TOTAL RECOMMENDED Savings:
$5,393
Cost:
$7,668
$5,188 133,041 $5 0 $64 - $136 - $5,188
133,041
kWh
$5
0
kW-months/year
$64
-
$
$136
-
$
TOTAL IMPLEMENTED Savings:
$5,283
Cost:
$7,631
$5,179 132,804 - - - - $104 - $5,179
132,804
kWh
-
-
kW-months/year
-
-
$
$104
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost Electricity Usage Electricity Demand Personnel Changes Ancillary Material Cost