IAC logo
IAC Assessment: AM0938
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0938
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2025
Principal Product Rolled Steel
NAICS 331221 - Rolled Steel Shape Manufacturing
SIC 3316 - Cold Finishing Of Steel Shapes
Sales $10,000,000-$50,000,000
# of Employees 35
Plant Area (Sq.Ft.) 127,500
Annual Production 50,000 Tons
Production Hrs. Annual 1,520
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $35,207 625,920 kWh $0.06
Electricity Demand $43,394 4,950 kW-months/year $8.77
Electricity Fees $8,030 - $ -
Natural Gas $380 1 MMBtu $379.57
TOTAL ENERGY COSTS $87,010
RECOMMENDED SAVINGS* $259,760 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $ $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$213,909
Cost:
$2,311,826
$213,909 3,819,815 - - - - - - $213,909
3,819,815
kWh
-
-
kW-months/year
-
-
$
-
-
$
02: 2.7273 INSTALL DESICCANT HUMIDITY CONTROL SYSTEM Savings:
$23,487
Cost:
$32,590
$15 267 - - - - $23,472 - $15
267
kWh
-
-
kW-months/year
-
-
$
$23,472
-
$
03: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$8,260
Cost:
$15,000
- - - - $8,260 - - - -
-
kWh
-
-
kW-months/year
$8,260
-
$
-
-
$
04: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$6,940
Cost:
$16,200
- - $6,940 792 - - - - -
-
kWh
$6,940
792
kW-months/year
-
-
$
-
-
$
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,804
Cost:
$29,010
$2,695 50,815 $1,450 165 $1,659 - - - $2,695
50,815
kWh
$1,450
165
kW-months/year
$1,659
-
$
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$1,360
Cost:
$10,180
$1,360 25,700 - - - - - - $1,360
25,700
kWh
-
-
kW-months/year
-
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$259,760
Cost:
$2,414,806
$217,979 3,896,597 $8,390 957 $9,919 - $23,472 - $217,979
3,896,597
kWh
$8,390
957
kW-months/year
$9,919
-
$
$23,472
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost Electricity Usage Electricity Demand Electricity Fees One-time Revenue or Avoided Cost