IAC logo
IAC Assessment: AM0951
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AM0951
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Texas A&M, College Station
Assessment Year 2025
Principal Product Elementary School Students
NAICS 611110 - Elementary and Secondary Schools
SIC 8211 - Elementary And Secondary Schools
Sales $1,000,000-$5,000,000
# of Employees 70
Plant Area (Sq.Ft.) 51,429
Annual Production 60 Units
Production Hrs. Annual 3,034
Location (State) TX
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $16,491 434,200 kWh $0.04
Electricity Demand $28,126 2,105 kW-months/year $13.36
Natural Gas $1,525 77 MMBtu $19.81
TOTAL ENERGY COSTS $46,142
RECOMMENDED SAVINGS* $10,448 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Electricity Usage Electricity Demand
$ kWh $ kW-months/year
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$1,007
Cost:
$4,909
$436 11,482 $571 43 $436
11,482
kWh
$571
43
kW-months/year
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$177
Cost:
$1,390
$177 4,648 - - $177
4,648
kWh
-
-
kW-months/year
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$8,637
Cost:
$117,000
$8,637 227,289 - - $8,637
227,289
kWh
-
-
kW-months/year
04: 2.7493 USE DOUBLE OR TRIPLE GLAZED WINDOWS TO MAINTAIN HIGHER RELATIVE HUMIDITY AND TO REDUCE HEAT LOSSES Savings:
$627
Cost:
$26,371
$627 16,505 - - $627
16,505
kWh
-
-
kW-months/year
TOTAL RECOMMENDED Savings:
$10,448
Cost:
$149,670
$9,877 259,924 $571 43 $9,877
259,924
kWh
$571
43
kW-months/year
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
kW-months/year
Savings
Cost
$ kWh $ kW-months/year
Electricity Usage Electricity Demand Electricity Usage Electricity Demand