Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1996 |
Principal Product | Aluminum Foil |
NAICS | n/a |
SIC | 3353 - Aluminum Sheet, Plate, And Foil |
Sales | $50,000,000-$100,000,000 |
# of Employees | 206 |
Plant Area (Sq.Ft.) | 179,500 |
Annual Production | 44,000,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $403,526 | 19,221,278 | kWh | $0.02 |
Electricity Demand | $563,384 | 33,238 | kW-months/year | $16.95 |
Natural Gas | $471,101 | 148,651 | MMBtu | $3.17 |
TOTAL ENERGY COSTS | $1,474,511 | |||
RECOMMENDED SAVINGS* | $39,421 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $35,121 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,044 Cost: $1,143 |
$1,569 | 74,736 | $2,475 | 146 | - | - |
$1,569 74,736 kWh |
$2,475 146 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $6,354 Cost: $2,920 |
$2,893 | 137,749 | $3,461 | 204 | - | - |
$2,893 137,749 kWh |
$3,461 204 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4234 COOL COMPRESSOR AIR INTAKE WITH HEAT EXCHANGER |
Savings: $13,886 Cost: $13,040 |
$6,943 | 233,001 | $6,943 | 410 | - | - |
$6,943 233,001 kWh |
$6,943 410 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,537 Cost: $200 |
$1,581 | 75,322 | $1,956 | 115 | - | - |
$1,581 75,322 kWh |
$1,956 115 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $4,300 Cost: - |
$1,668 | 79,426 | $2,632 | 155 | - | - |
$1,668 79,426 kWh |
$2,632 155 kW-months/year |
- - gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.7311 MAINTAIN MACHINES TO REDUCE LEAKS |
Savings: $7,300 Cost: $600 |
- | - | - | - | $7,300 | 730 |
- - kWh |
- - kW-months/year |
$7,300 730 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $39,421 Cost: $17,903 |
$14,654 | 600,234 | $17,467 | 1,030 | $7,300 | 730 | $14,654 600,234 kWh |
$17,467 1,030 kW-months/year |
$7,300 730 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $35,121 Cost: $17,903 |
$12,986 | 520,808 | $14,835 | 875 | $7,300 | 730 | $12,986 520,808 kWh |
$14,835 875 kW-months/year |
$7,300 730 gal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (haz) | Electricity Usage | Electricity Demand | Other Liquid (haz) |