Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 1998 |
Principal Product | Plastic Bathroom Accessories |
NAICS | n/a |
SIC | 3089 - Plastics Products, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 90 |
Plant Area (Sq.Ft.) | 81,000 |
Annual Production | 290,000 Pieces |
Production Hrs. Annual | 4,693 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $106,518 | 3,208,675 | kWh | $0.03 |
Electricity Demand | $119,794 | 10,785 | kW-months/year | $11.11 |
Natural Gas | $49,770 | 9,923 | MMBtu | $5.02 |
TOTAL ENERGY COSTS | $276,204 | |||
RECOMMENDED SAVINGS* | $317,123 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $106,877 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $99 Cost: $207 |
$53 | 1,758 | $46 | 4 | - | - | - | - | - | - | - | - |
$53 1,758 kWh |
$46 4 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $49,699 Cost: $135,000 |
$28,024 | 1,300,410 | $28,949 | 2,606 | $(-7,274) | (-1,449) | - | - | - | - | - | - |
$28,024 1,300,410 kWh |
$28,949 2,606 kW-months/year |
$(-7,274) (-1,449) MMBtu |
- - Tgal |
- - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4115 RECOVER AND REUSE COOLING WATER |
Savings: $4,517 Cost: $6,800 |
$(-232) | (-7,034) | $(-200) | (-18) | - | - | $104 | 52,092 | - | - | $4,845 | - |
$(-232) (-7,034) kWh |
$(-200) (-18) kW-months/year |
- - MMBtu |
$104 52,092 Tgal |
- - $ |
$4,845 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $210,246 Cost: $35,000 |
- | - | - | - | - | - | - | - | $210,246 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$210,246 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.514 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS |
Savings: $52,562 Cost: - |
- | - | - | - | - | - | - | - | $52,562 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$52,562 - $ |
- - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $317,123 Cost: $177,007 |
$27,845 | 1,295,134 | $28,795 | 2,592 | $(-7,274) | (-1,449) | $104 | 52,092 | $262,808 | - | $4,845 | - | $27,845 1,295,134 kWh |
$28,795 2,592 kW-months/year |
$(-7,274) (-1,449) MMBtu |
$104 52,092 Tgal |
$262,808 - $ |
$4,845 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $106,877 Cost: $142,007 |
$27,845 | 1,295,134 | $28,795 | 2,592 | $(-7,274) | (-1,449) | $104 | 52,092 | $52,562 | - | $4,845 | - | $27,845 1,295,134 kWh |
$28,795 2,592 kW-months/year |
$(-7,274) (-1,449) MMBtu |
$104 52,092 Tgal |
$52,562 - $ |
$4,845 - Tgal |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Water Consumption |