Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Arkansas |
---|---|
Assessment Year | 2000 |
Principal Product | Folding Cartons |
NAICS | n/a |
SIC | 2657 - Folding Paperboard Boxes |
Sales | $50,000,000-$100,000,000 |
# of Employees | 270 |
Plant Area (Sq.Ft.) | 265,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 8,568 |
Location (State) | AR |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $286,398 | 9,051,583 | kWh | $0.03 |
Electricity Demand | $126,063 | 18,676 | kW-months/year | $6.75 |
Natural Gas | $71,827 | 15,804 | MMBtu | $4.54 |
TOTAL ENERGY COSTS | $488,510 | |||
RECOMMENDED SAVINGS* | $279,710 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Disposal | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Water Disposal | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4314 USE SYNTHETIC LUBRICANT |
Savings: $2,906 Cost: - |
$2,348 | 55,979 | $558 | 83 | - | - | - | - | - | - |
$2,348 55,979 kWh |
$558 83 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,227 Cost: $5,679 |
$2,628 | 63,306 | $599 | 89 | - | - | - | - | - | - |
$2,628 63,306 kWh |
$599 89 kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.5113 SELL OIL TO RECYCLER |
Savings: $1,436 Cost: $1,500 |
- | - | - | - | $1,436 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,436 - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $269,892 Cost: $15,800 |
- | - | - | - | - | - | $269,892 | - | - | - |
- - kWh |
- - kW-months/year |
- - Tgal |
$269,892 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.513 RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS |
Savings: $2,249 Cost: $110 |
- | - | - | - | - | - | - | - | $2,249 | - |
- - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
$2,249 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $279,710 Cost: $23,089 |
$4,976 | 119,285 | $1,157 | 172 | $1,436 | - | $269,892 | - | $2,249 | - | $4,976 119,285 kWh |
$1,157 172 kW-months/year |
$1,436 - Tgal |
$269,892 - $ |
$2,249 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - Tgal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Disposal | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Water Disposal | Primary Product | By-product Production |