Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 1999 |
Principal Product | Aircraft Component Parts |
NAICS | n/a |
SIC | 3728 - Aircraft Parts And Equipment, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 60 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 60,000 Pieces |
Production Hrs. Annual | 6,120 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $105,101 | 1,767,878 | kWh | $0.06 |
Electricity Demand | $13,757 | 4,943 | kW-months/year | $2.78 |
Electricity Fees | $10,080 | - | $ | - |
TOTAL ENERGY COSTS | $138,672 | |||
RECOMMENDED SAVINGS* | $26,552 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,651 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,589 Cost: $21,494 |
$4,640 | 115,768 | $1,949 | 172 | - | - | - | - | - | - |
$4,640 115,768 kWh |
$1,949 172 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $1,057 Cost: $166 |
$681 | 16,999 | $376 | 33 | - | - | - | - | - | - |
$681 16,999 kWh |
$376 33 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $285 Cost: $319 |
$138 | 3,517 | $41 | 4 | $52 | - | - | - | $54 | - |
$138 3,517 kWh |
$41 4 kW-months/year |
$52 - $ |
- - $ |
$54 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $12,722 Cost: $10,500 |
$9,179 | 228,898 | $3,543 | 318 | - | - | - | - | - | - |
$9,179 228,898 kWh |
$3,543 318 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7424 SHADE WINDOWS FROM SUMMER SUN |
Savings: $1,062 Cost: $980 |
$1,062 | 26,377 | - | - | - | - | - | - | - | - |
$1,062 26,377 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT |
Savings: $1,852 Cost: $3,385 |
$306 | (-6,448) | $1,546 | 137 | - | - | - | - | - | - |
$306 (-6,448) kWh |
$1,546 137 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $925 Cost: $120 |
- | - | - | - | - | - | $925 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$925 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.812 APPLY FOR INVESTMENT INCENTIVES |
Savings: $2,060 Cost: $60 |
- | - | - | - | - | - | $2,060 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,060 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $26,552 Cost: $37,024 |
$16,006 | 385,111 | $7,455 | 664 | $52 | - | $2,985 | - | $54 | - | $16,006 385,111 kWh |
$7,455 664 kW-months/year |
$52 - $ |
$2,985 - $ |
$54 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,651 Cost: $25,318 |
$5,084 | 112,837 | $3,536 | 313 | $52 | - | $925 | - | $54 | - | $5,084 112,837 kWh |
$3,536 313 kW-months/year |
$52 - $ |
$925 - $ |
$54 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |