Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2000 |
Principal Product | General Repairs, Production, Custom Fabrication |
NAICS | n/a |
SIC | 3599 - Industrial Machinery, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 16 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 600 Pieces |
Production Hrs. Annual | 2,625 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $21,892 | 252,931 | kWh | $0.09 |
Electricity Demand | $1,082 | 732 | kW-months/year | $1.48 |
Electricity Fees | $1,840 | - | $ | - |
Natural Gas | $6,176 | 789 | MMBtu | $7.83 |
TOTAL ENERGY COSTS | $32,095 | |||
RECOMMENDED SAVINGS* | $276,989 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $273,112 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,324 Cost: $6,008 |
$1,798 | 23,447 | $526 | 97 | - | - | - | - |
$1,798 23,447 kWh |
$526 97 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $896 Cost: $300 |
$734 | 9,672 | $162 | 30 | - | - | - | - |
$734 9,672 kWh |
$162 30 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $2,275 Cost: $1,890 |
$2,275 | 29,894 | - | - | - | - | - | - |
$2,275 29,894 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $1,608 Cost: $200 |
$1,215 | 15,826 | $393 | 73 | - | - | - | - |
$1,215 15,826 kWh |
$393 73 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $516 Cost: $60 |
- | - | - | - | $516 | - | - | - |
- - kWh |
- - kW-months/year |
$516 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $190 Cost: $95 |
- | - | - | - | $190 | - | - | - |
- - kWh |
- - kW-months/year |
$190 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.421 MODIFY CURRENT INCENTIVE PROGRAM |
Savings: $269,180 Cost: $100,000 |
- | - | - | - | - | - | $269,180 | - |
- - kWh |
- - kW-months/year |
- - $ |
$269,180 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $276,989 Cost: $108,553 |
$6,022 | 78,839 | $1,081 | 200 | $706 | - | $269,180 | - | $6,022 78,839 kWh |
$1,081 200 kW-months/year |
$706 - $ |
$269,180 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $273,112 Cost: $106,208 |
$3,013 | 39,273 | $919 | 170 | - | - | $269,180 | - | $3,013 39,273 kWh |
$919 170 kW-months/year |
- - $ |
$269,180 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product |