IAC logo
IAC Assessment: AS0270
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AS0270
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2000
Principal Product General Repairs, Production, Custom Fabrication
NAICS n/a
SIC 3599 - Industrial Machinery, Nec
Sales $1,000,000-$5,000,000
# of Employees 16
Plant Area (Sq.Ft.) 50,000
Annual Production 600 Pieces
Production Hrs. Annual 2,625
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $21,892 252,931 kWh $0.09
Electricity Demand $1,082 732 kW-months/year $1.48
Electricity Fees $1,840 - $ -
Natural Gas $6,176 789 MMBtu $7.83
TOTAL ENERGY COSTS $32,095
RECOMMENDED SAVINGS* $276,989 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $273,112
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Primary Product Electricity Usage Electricity Demand Administrative Changes Primary Product
$ kWh $ kW-months/year $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,324
Cost:
$6,008
$1,798 23,447 $526 97 - - - - $1,798
23,447
kWh
$526
97
kW-months/year
-
-
$
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$896
Cost:
$300
$734 9,672 $162 30 - - - - $734
9,672
kWh
$162
30
kW-months/year
-
-
$
-
-
$
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT Savings:
$2,275
Cost:
$1,890
$2,275 29,894 - - - - - - $2,275
29,894
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$1,608
Cost:
$200
$1,215 15,826 $393 73 - - - - $1,215
15,826
kWh
$393
73
kW-months/year
-
-
$
-
-
$
05: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$516
Cost:
$60
- - - - $516 - - - -
-
kWh
-
-
kW-months/year
$516
-
$
-
-
$
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL Savings:
$190
Cost:
$95
- - - - $190 - - - -
-
kWh
-
-
kW-months/year
$190
-
$
-
-
$
07: 4.421 MODIFY CURRENT INCENTIVE PROGRAM Savings:
$269,180
Cost:
$100,000
- - - - - - $269,180 - -
-
kWh
-
-
kW-months/year
-
-
$
$269,180
-
$
TOTAL RECOMMENDED Savings:
$276,989
Cost:
$108,553
$6,022 78,839 $1,081 200 $706 - $269,180 - $6,022
78,839
kWh
$1,081
200
kW-months/year
$706
-
$
$269,180
-
$
TOTAL IMPLEMENTED Savings:
$273,112
Cost:
$106,208
$3,013 39,273 $919 170 - - $269,180 - $3,013
39,273
kWh
$919
170
kW-months/year
-
-
$
$269,180
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Administrative Changes Primary Product Electricity Usage Electricity Demand Administrative Changes Primary Product