Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2000 |
Principal Product | Wood and Laminated Office and Store Fixtures |
NAICS | n/a |
SIC | 2431 - Millwork |
Sales | $5,000,000-$10,000,000 |
# of Employees | 86 |
Plant Area (Sq.Ft.) | 91,000 |
Annual Production | 2,500,000 Pounds |
Production Hrs. Annual | 2,431 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $58,471 | 943,728 | kWh | $0.06 |
Electricity Demand | $9,409 | 3,606 | kW-months/year | $2.61 |
Electricity Fees | $6,280 | - | $ | - |
TOTAL ENERGY COSTS | $74,160 | |||
RECOMMENDED SAVINGS* | $30,928 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $17,320 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $1,064 Cost: $2,486 |
$719 | 12,896 | $345 | 59 | - | - | - | - | - | - |
$719 12,896 kWh |
$345 59 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,003 Cost: $800 |
$1,003 | 17,878 | - | - | - | - | - | - | - | - |
$1,003 17,878 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $10,564 Cost: $3,800 |
$6,987 | 123,974 | $3,577 | 612 | - | - | - | - | - | - |
$6,987 123,974 kWh |
$3,577 612 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,270 Cost: $60 |
$1,270 | 22,567 | - | - | - | - | - | - | - | - |
$1,270 22,567 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $809 Cost: $100 |
$535 | 9,379 | $274 | 47 | - | - | - | - | - | - |
$535 9,379 kWh |
$274 47 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $852 Cost: $60 |
- | - | - | - | - | - | - | - | $852 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$852 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5217 REUSE / RECYCLE/ SELL PAPER PRODUCTS |
Savings: $315 Cost: $60 |
- | - | - | - | $315 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$315 - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.821 PAY BILLS ON TIME TO AVOID LATE FEES |
Savings: $771 Cost: $60 |
- | - | - | - | - | - | - | - | $771 | - |
- - kWh |
- - kW-months/year |
- - lb |
- - $ |
$771 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.432 CROSS-TRAIN PERSONNEL TO AVOID LOST TIME |
Savings: $14,280 Cost: $2,240 |
- | - | - | - | - | - | $14,280 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$14,280 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $30,928 Cost: $9,666 |
$10,514 | 186,694 | $4,196 | 718 | $315 | - | $14,280 | - | $1,623 | - | $10,514 186,694 kWh |
$4,196 718 kW-months/year |
$315 - lb |
$14,280 - $ |
$1,623 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $17,320 Cost: $4,946 |
$1,254 | 22,275 | $619 | 106 | $315 | - | $14,280 | - | $852 | - | $1,254 22,275 kWh |
$619 106 kW-months/year |
$315 - lb |
$14,280 - $ |
$852 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | Administrative Changes |