Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2001 |
Principal Product | Aluminum Extruded Products for Aircraft Applications |
NAICS | n/a |
SIC | 3354 - Aluminum Extruded Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 124 |
Plant Area (Sq.Ft.) | 35,000 |
Annual Production | 21,000,000 Pounds |
Production Hrs. Annual | 5,400 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $480,870 | 16,029,000 | kWh | $0.03 |
Electricity Demand | $357,966 | 55,072 | kW-months/year | $6.50 |
Electricity Fees | $54,608 | - | $ | - |
Natural Gas | $221,652 | 66,407 | MMBtu | $3.34 |
TOTAL ENERGY COSTS | $1,120,955 | |||
RECOMMENDED SAVINGS* | $184,726 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $2,245 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Primary Product | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $2,245 Cost: $540 |
$1,009 | 31,546 | $1,236 | 179 | - | - | - | - |
$1,009 31,546 kWh |
$1,236 179 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,097 Cost: $60 |
$807 | 25,230 | $290 | 42 | - | - | - | - |
$807 25,230 kWh |
$290 42 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $1,246 Cost: $1,575 |
$1,246 | 36,223 | - | - | - | - | - | - |
$1,246 36,223 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $3,681 Cost: $12,153 |
$2,706 | 84,559 | $975 | 141 | - | - | - | - |
$2,706 84,559 kWh |
$975 141 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,330 Cost: $60 |
- | - | - | - | - | - | $2,330 | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,330 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.6192 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL |
Savings: $2,727 Cost: $60 |
- | - | - | - | - | - | $2,727 | - |
- - kWh |
- - kW-months/year |
- - $ |
$2,727 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.431 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY |
Savings: $156,400 Cost: $11,520 |
- | - | - | - | $156,400 | - | - | - |
- - kWh |
- - kW-months/year |
$156,400 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.232 LEASE EQUIPMENT INSTEAD OF PURCHASING |
Savings: $15,000 Cost: $1,200 |
- | - | - | - | $15,000 | - | - | - |
- - kWh |
- - kW-months/year |
$15,000 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $184,726 Cost: $27,168 |
$5,768 | 177,558 | $2,501 | 362 | $171,400 | - | $5,057 | - | $5,768 177,558 kWh |
$2,501 362 kW-months/year |
$171,400 - $ |
$5,057 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $2,245 Cost: $540 |
$1,009 | 31,546 | $1,236 | 179 | - | - | - | - | $1,009 31,546 kWh |
$1,236 179 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Primary Product | By-product Production | Electricity Usage | Electricity Demand | Primary Product | By-product Production |