Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2020 |
Principal Product | Insulated Conductors |
NAICS | 335929 - Other Communication and Energy Wire Manufacturing |
SIC | 3357 - Nonferrous Wiredrawing & Insulating |
Sales | <$500,000 |
# of Employees | 78 |
Plant Area (Sq.Ft.) | 100,000 |
Annual Production | 200,000 Thousand Feet |
Production Hrs. Annual | 6,240 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $408,876 | 4,754,377 | kWh | $0.09 |
Electricity Demand | $77,897 | 15,274 | kW-months/year | $5.10 |
TOTAL ENERGY COSTS | $486,773 | |||
RECOMMENDED SAVINGS* | $605,664 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.113 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT |
Savings: $502,983 Cost: $7,794 |
$(-563) | (-6,552) | $(-184) | (-36) | - | - | $503,730 | - |
$(-563) (-6,552) kWh |
$(-184) (-36) kW-months/year |
- - $ |
$503,730 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $51,986 Cost: $394,050 |
$46,514 | 747,526 | $5,472 | 785 | - | - | - | - |
$46,514 747,526 kWh |
$5,472 785 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $21,819 Cost: $29,360 |
$18,514 | 215,280 | $3,305 | 648 | - | - | - | - |
$18,514 215,280 kWh |
$3,305 648 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $16,784 Cost: $10,912 |
$15,470 | 179,893 | $1,217 | 239 | $97 | - | - | - |
$15,470 179,893 kWh |
$1,217 239 kW-months/year |
$97 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $12,092 Cost: $5,188 |
$10,878 | 126,487 | $1,214 | 238 | - | - | - | - |
$10,878 126,487 kWh |
$1,214 238 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $605,664 Cost: $447,304 |
$90,813 | 1,262,634 | $11,024 | 1,874 | $97 | - | $503,730 | - | $90,813 1,262,634 kWh |
$11,024 1,874 kW-months/year |
$97 - $ |
$503,730 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Increase in Production | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Increase in Production |