Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2020 |
Principal Product | Treated Wastewater |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | <$500,000 |
# of Employees | 10 |
Plant Area (Sq.Ft.) | 50,000 |
Annual Production | 1,348,000 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $230,885 | 5,359,789 | kWh | $0.04 |
Electricity Demand | $211,287 | 11,220 | kW-months/year | $18.83 |
Electricity Fees | $38,193 | - | $ | - |
Natural Gas | $64,089 | 10,914 | MMBtu | $5.87 |
TOTAL ENERGY COSTS | $544,454 | |||
RECOMMENDED SAVINGS* | $153,862 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $153,636 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $130,212 Cost: $564 |
$49,706 | 1,155,948 | $80,506 | 4,275 | - | - |
$49,706 1,155,948 kWh |
$80,506 4,275 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,021 Cost: $31,867 |
$8,287 | 192,732 | $4,935 | 262 | $(-1,201) | - |
$8,287 192,732 kWh |
$4,935 262 kW-months/year |
$(-1,201) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6125 KEEP EQUIPMENT CLEAN |
Savings: $3,890 Cost: $2,174 |
$3,890 | 96,490 | - | - | - | - |
$3,890 96,490 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,827 Cost: $2,905 |
$3,827 | 89,005 | - | - | - | - |
$3,827 89,005 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.8112 COMBINE UTILITY METERS |
Savings: $3,107 Cost: $1,473 |
$(-8,921) | - | $9,849 | - | $2,179 | - |
$(-8,921) - kWh |
$9,849 - kW-months/year |
$2,179 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $518 Cost: $382 |
$337 | 7,840 | $181 | 10 | - | - |
$337 7,840 kWh |
$181 10 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $226 Cost: $354 |
$139 | 3,229 | $87 | 5 | - | - |
$139 3,229 kWh |
$87 5 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT |
Savings: $61 Cost: $47 |
$38 | 891 | $23 | 1 | - | - |
$38 891 kWh |
$23 1 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $153,862 Cost: $39,766 |
$57,303 | 1,546,135 | $95,581 | 4,553 | $978 | - | $57,303 1,546,135 kWh |
$95,581 4,553 kW-months/year |
$978 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $153,636 Cost: $39,412 |
$57,164 | 1,542,906 | $95,494 | 4,548 | $978 | - | $57,164 1,542,906 kWh |
$95,494 4,548 kW-months/year |
$978 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |