Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2021 |
Principal Product | Dehydrated Fruits |
NAICS | 311423 - Dried and Dehydrated Food Manufacturing |
SIC | 2034 - Dehydrated Fruits, Vegetables, Soups |
Sales | <$500,000 |
# of Employees | 200 |
Plant Area (Sq.Ft.) | 45,000 |
Annual Production | 20,000,000 Units |
Production Hrs. Annual | 3,998 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $207,258 | 2,838,080 | kWh | $0.07 |
Electricity Demand | $67,740 | 6,703 | kW-months/year | $10.11 |
Electricity Fees | $9,080 | - | $ | - |
TOTAL ENERGY COSTS | $284,078 | |||
RECOMMENDED SAVINGS* | $262,427 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $182,262 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 3.1162 USE LESS WASTEFUL PACKAGING |
Savings: $178,199 Cost: $183,215 |
- | - | - | - | $178,199 | - |
- - kWh |
- - kW-months/year |
$178,199 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $67,347 Cost: $326,860 |
$56,614 | 775,537 | $10,733 | 1,062 | - | - |
$56,614 775,537 kWh |
$10,733 1,062 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $6,366 Cost: $14,494 |
$5,564 | 76,208 | $1,270 | 126 | $(-468) | - |
$5,564 76,208 kWh |
$1,270 126 kW-months/year |
$(-468) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE |
Savings: $4,270 Cost: $200 |
$25,713 | - | $(-21,443) | - | - | - |
$25,713 - kWh |
$(-21,443) - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6125 KEEP EQUIPMENT CLEAN |
Savings: $4,063 Cost: $464 |
$2,658 | 36,412 | $1,405 | 139 | - | - |
$2,658 36,412 kWh |
$1,405 139 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,149 Cost: $1,295 |
$1,149 | 15,753 | - | - | - | - |
$1,149 15,753 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $1,033 Cost: $3,432 |
$868 | 11,895 | $165 | 16 | - | - |
$868 11,895 kWh |
$165 16 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $262,427 Cost: $529,960 |
$92,566 | 915,805 | $(-7,870) | 1,343 | $177,731 | - | $92,566 915,805 kWh |
$(-7,870) 1,343 kW-months/year |
$177,731 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $182,262 Cost: $183,679 |
$2,658 | 36,412 | $1,405 | 139 | $178,199 | - | $2,658 36,412 kWh |
$1,405 139 kW-months/year |
$178,199 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost |