Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2022 |
Principal Product | Archery Equipment |
NAICS | 339920 - Sporting and Athletic Goods Manufacturing |
SIC | 3949 - Sporting And Athletic Goods, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 198 |
Plant Area (Sq.Ft.) | 78,600 |
Annual Production | 33,000 Units |
Production Hrs. Annual | 8,640 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $170,999 | 3,457,616 | kWh | $0.05 |
Electricity Demand | $147,734 | 7,690 | kW-months/year | $19.21 |
Electricity Fees | $63,906 | - | $ | - |
TOTAL ENERGY COSTS | $382,639 | |||
RECOMMENDED SAVINGS* | $181,278 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $138,858 Cost: $8,368 |
$40,548 | 819,159 | $(-1,690) | 88 | - | - | $100,000 | - |
$40,548 819,159 kWh |
$(-1,690) 88 kW-months/year |
- - $ |
$100,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $10,545 Cost: $141,340 |
$7,092 | 155,157 | $3,453 | 186 | - | - | - | - |
$7,092 155,157 kWh |
$3,453 186 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $9,435 Cost: $4,628 |
$5,535 | 111,824 | $3,900 | 203 | - | - | - | - |
$5,535 111,824 kWh |
$3,900 203 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $9,222 Cost: $8,635 |
$3,082 | 62,249 | $5,934 | 309 | $206 | - | - | - |
$3,082 62,249 kWh |
$5,934 309 kW-months/year |
$206 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7263 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION |
Savings: $7,266 Cost: $30,762 |
$4,748 | 95,920 | $2,518 | 131 | - | - | - | - |
$4,748 95,920 kWh |
$2,518 131 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $3,883 Cost: $1,160 |
$2,058 | 41,580 | $1,825 | 95 | - | - | - | - |
$2,058 41,580 kWh |
$1,825 95 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $799 Cost: $1,584 |
$431 | 8,699 | $368 | 19 | - | - | - | - |
$431 8,699 kWh |
$368 19 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $772 Cost: $59 |
$503 | 10,165 | $269 | 14 | - | - | - | - |
$503 10,165 kWh |
$269 14 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $498 Cost: $216 |
$498 | 10,056 | - | - | - | - | - | - |
$498 10,056 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $181,278 Cost: $196,752 |
$64,495 | 1,314,809 | $16,577 | 1,045 | $206 | - | $100,000 | - | $64,495 1,314,809 kWh |
$16,577 1,045 kW-months/year |
$206 - $ |
$100,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | One-time Revenue or Avoided Cost | Primary Product |