Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2022 |
Principal Product | engraving machines |
NAICS | 423710 - Hardware Merchant Wholesalers |
SIC | 5072 - Hardware |
Sales | $100,000,000-$500,000,000 |
# of Employees | 150 |
Plant Area (Sq.Ft.) | 137,000 |
Annual Production | 5,400 Units |
Production Hrs. Annual | 2,184 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $148,666 | 2,245,458 | kWh | $0.07 |
Electricity Demand | $55,731 | 6,746 | kW-months/year | $8.26 |
Electricity Fees | $10,775 | - | $ | - |
TOTAL ENERGY COSTS | $215,172 | |||
RECOMMENDED SAVINGS* | $86,036 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,362 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $57,834 Cost: $453,050 |
$49,161 | 742,612 | $8,673 | 1,050 | - | - |
$49,161 742,612 kWh |
$8,673 1,050 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $15,662 Cost: $30,425 |
$11,171 | 168,749 | $3,705 | 449 | $786 | - |
$11,171 168,749 kWh |
$3,705 449 kW-months/year |
$786 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7272 INSTALL HEAT PIPES / RAISE COOLING SETPOINT |
Savings: $11,409 Cost: $630 |
$6,841 | 103,334 | $4,568 | 553 | - | - |
$6,841 103,334 kWh |
$4,568 553 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7444 CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS |
Savings: $597 Cost: $163 |
$407 | 6,150 | $190 | 23 | - | - |
$407 6,150 kWh |
$190 23 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $291 Cost: $600 |
$291 | 4,391 | - | - | - | - |
$291 4,391 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7496 INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE |
Savings: $243 Cost: $852 |
$165 | 2,499 | $78 | 9 | - | - |
$165 2,499 kWh |
$78 9 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $86,036 Cost: $485,720 |
$68,036 | 1,027,735 | $17,214 | 2,084 | $786 | - | $68,036 1,027,735 kWh |
$17,214 2,084 kW-months/year |
$786 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,362 Cost: $31,655 |
$18,303 | 276,474 | $8,273 | 1,002 | $786 | - | $18,303 276,474 kWh |
$8,273 1,002 kW-months/year |
$786 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Ancillary Material Cost | Electricity Usage | Electricity Demand | Ancillary Material Cost |