Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2023
Principal Product Refrigerated produce
NAICS 493120 - Refrigerated Warehousing and Storage
SIC 4222 - Refrigerated Warehousing And Storage
Sales $1,000,000-$5,000,000
# of Employees 10
Plant Area (Sq.Ft.) 25,000
Annual Production 1 Pounds
Production Hrs. Annual 8,760
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $52,340 558,960 kWh $0.09
Electricity Demand $30,215 2,023 kW-months/year $14.94
TOTAL ENERGY COSTS $82,555
RECOMMENDED SAVINGS* $47,024 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $47,024
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost
$ kWh $ kW-months/year $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$28,395
Cost:
$281,442
$25,040 267,526 $3,355 225 - - $25,040
267,526
kWh
$3,355
225
kW-months/year
-
-
$
02: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$5,520
Cost:
$2,832
$3,958 42,282 $1,562 105 - - $3,958
42,282
kWh
$1,562
105
kW-months/year
-
-
$
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,704
Cost:
$6,059
$1,813 19,372 $1,524 102 $367 - $1,813
19,372
kWh
$1,524
102
kW-months/year
$367
-
$
04: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$2,798
Cost:
$2,970
$1,831 19,564 $967 65 - - $1,831
19,564
kWh
$967
65
kW-months/year
-
-
$
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$2,680
Cost:
$600
$2,680 28,632 - - - - $2,680
28,632
kWh
-
-
kW-months/year
-
-
$
06: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS Savings:
$1,609
Cost:
$1,858
$1,609 17,186 - - - - $1,609
17,186
kWh
-
-
kW-months/year
-
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,513
Cost:
$1,560
$823 8,791 $690 46 - - $823
8,791
kWh
$690
46
kW-months/year
-
-
$
08: 2.7134 USE PHOTOCELL CONTROLS Savings:
$805
Cost:
$1,700
$569 6,088 $236 16 - - $569
6,088
kWh
$236
16
kW-months/year
-
-
$
TOTAL RECOMMENDED Savings:
$47,024
Cost:
$299,021
$38,323 409,441 $8,334 559 $367 - $38,323
409,441
kWh
$8,334
559
kW-months/year
$367
-
$
TOTAL IMPLEMENTED Savings:
$47,024
Cost:
$299,021
$38,323 409,441 $8,334 559 $367 - $38,323
409,441
kWh
$8,334
559
kW-months/year
$367
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Ancillary Material Cost Electricity Usage Electricity Demand Ancillary Material Cost