Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2023 |
Principal Product | general aviation/fuel |
NAICS | 488119 - Other Airport Operations |
SIC | 4581 - Airports, Flying Fields, & Services |
Sales | $1,000,000-$5,000,000 |
# of Employees | 16 |
Plant Area (Sq.Ft.) | 347,859 |
Annual Production | 1 Units |
Production Hrs. Annual | 8,760 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $17,631 | 172,430 | kWh | $0.10 |
Electricity Demand | $3,890 | 475 | kW-months/year | $8.19 |
Electricity Fees | $16,221 | - | $ | - |
Natural Gas | $6,669 | 250 | MMBtu | $26.68 |
Other Gas | $452,747 | 10,708 | MMBtu | $42.28 |
TOTAL ENERGY COSTS | $497,158 | |||
RECOMMENDED SAVINGS* | $12,495 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $5,534 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS |
Savings: $5,610 Cost: $960 |
- | - | - | - | - | - | - | - | $5,610 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$5,610 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,169 Cost: $2,419 |
$2,100 | 20,591 | $440 | 54 | - | - | $629 | - | - | - |
$2,100 20,591 kWh |
$440 54 kW-months/year |
- - $ |
$629 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $1,986 Cost: $19,728 |
$1,866 | 18,292 | $120 | 15 | - | - | - | - | - | - |
$1,866 18,292 kWh |
$120 15 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,118 Cost: $160 |
$973 | 9,538 | $145 | 18 | - | - | - | - | - | - |
$973 9,538 kWh |
$145 18 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $333 Cost: $284 |
$285 | 2,799 | $48 | 6 | - | - | - | - | - | - |
$285 2,799 kWh |
$48 6 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4151 MINIMIZE WATER USAGE |
Savings: $233 Cost: $30 |
- | - | - | - | $233 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$233 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $46 Cost: $294 |
$46 | 449 | - | - | - | - | - | - | - | - |
$46 449 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $12,495 Cost: $23,875 |
$5,270 | 51,669 | $753 | 93 | $233 | - | $629 | - | $5,610 | - | $5,270 51,669 kWh |
$753 93 kW-months/year |
$233 - $ |
$629 - $ |
$5,610 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $5,534 Cost: $22,725 |
$4,297 | 42,131 | $608 | 75 | - | - | $629 | - | - | - | $4,297 42,131 kWh |
$608 75 kW-months/year |
- - $ |
$629 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | Primary Product |