Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2023 |
Principal Product | Office Space Rentals |
NAICS | 531120 - Lessors of Nonresidential Buildings (except Miniwarehouses) |
SIC | 6512 - Nonresidential Building Operators |
Sales | $500,000-$1,000,000 |
# of Employees | 5 |
Plant Area (Sq.Ft.) | 14,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 2,880 |
Location (State) | AZ |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $31,934 | 278,296 | kWh | $0.11 |
Electricity Demand | $10,735 | 931 | kW-months/year | $11.53 |
Electricity Fees | $6,005 | - | $ | - |
Natural Gas | $1,238 | 56 | MMBtu | $22.11 |
Other Gas | $1,181 | 32 | MMBtu | $36.91 |
TOTAL ENERGY COSTS | $51,093 | |||
RECOMMENDED SAVINGS* | $23,890 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $13,353 Cost: $72,205 |
$12,595 | 109,811 | $758 | 66 | - | - | - | - | - | - |
$12,595 109,811 kWh |
$758 66 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $4,678 Cost: $20,940 |
$3,777 | 32,931 | $263 | 23 | $1,238 | 56 | - | - | $(-600) | - |
$3,777 32,931 kWh |
$263 23 kW-months/year |
$1,238 56 MMBtu |
- - $ |
$(-600) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE |
Savings: $2,395 Cost: $4,200 |
$2,395 | 20,881 | - | - | - | - | - | - | - | - |
$2,395 20,881 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,168 Cost: $3,380 |
$1,802 | 15,708 | $226 | 20 | - | - | $140 | - | - | - |
$1,802 15,708 kWh |
$226 20 kW-months/year |
- - MMBtu |
$140 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $691 Cost: $1,099 |
$614 | 5,357 | $77 | 7 | - | - | - | - | - | - |
$614 5,357 kWh |
$77 7 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $425 Cost: $200 |
$378 | 3,293 | $47 | 4 | - | - | - | - | - | - |
$378 3,293 kWh |
$47 4 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7423 REDUCE HEAT GAIN BY WINDOW TINTING |
Savings: $180 Cost: $130 |
$160 | 1,396 | $20 | 2 | - | - | - | - | - | - |
$160 1,396 kWh |
$20 2 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $23,890 Cost: $102,154 |
$21,721 | 189,377 | $1,391 | 121 | $1,238 | 56 | $140 | - | $(-600) | - | $21,721 189,377 kWh |
$1,391 121 kW-months/year |
$1,238 56 MMBtu |
$140 - $ |
$(-600) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | One-time Revenue or Avoided Cost |