IAC logo
IAC Assessment: AS0577
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AS0577
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Arizona State University
Assessment Year 2024
Principal Product Canned foods
NAICS 311421 - Fruit and Vegetable Canning
SIC 2033 - Canned Fruits And Vegetables
Sales $50,000,000-$100,000,000
# of Employees 210
Plant Area (Sq.Ft.) 512,378
Annual Production 7,000,000 Units
Production Hrs. Annual 6,240
Location (State) AZ
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $791,943 12,224,268 kWh $0.06
Electricity Demand $544,587 28,614 kW-months/year $19.03
Electricity Fees $283,135 - $ -
Natural Gas $1,232,702 400,793 MMBtu $3.08
TOTAL ENERGY COSTS $3,652,755
RECOMMENDED SAVINGS* $549,502 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$242,289
Cost:
$2,885,843
$213,386 3,292,993 $28,903 1,519 - - - - $213,386
3,292,993
kWh
$28,903
1,519
kW-months/year
-
-
MMBtu
-
-
$
02: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$165,792
Cost:
$921,043
$118,820 1,833,640 $46,972 2,468 - - - - $118,820
1,833,640
kWh
$46,972
2,468
kW-months/year
-
-
MMBtu
-
-
$
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$51,679
Cost:
$30,000
- - - - $51,679 16,779 - - -
-
kWh
-
-
kW-months/year
$51,679
16,779
MMBtu
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$43,824
Cost:
$34,114
$25,905 399,782 $10,249 538 - - $7,670 - $25,905
399,782
kWh
$10,249
538
kW-months/year
-
-
MMBtu
$7,670
-
$
05: 2.4224 UPGRADE CONTROLS ON COMPRESSORS Savings:
$20,991
Cost:
$20,000
$15,042 232,128 $5,949 313 - - - - $15,042
232,128
kWh
$5,949
313
kW-months/year
-
-
MMBtu
-
-
$
06: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$14,086
Cost:
$15,866
$14,086 217,377 - - - - - - $14,086
217,377
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE Savings:
$9,172
Cost:
$2,798
$6,573 101,439 $2,599 137 - - - - $6,573
101,439
kWh
$2,599
137
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,281
Cost:
$406
$920 14,199 $361 19 - - - - $920
14,199
kWh
$361
19
kW-months/year
-
-
MMBtu
-
-
$
09: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS Savings:
$388
Cost:
$1,579
$278 4,294 $110 6 - - - - $278
4,294
kWh
$110
6
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$549,502
Cost:
$3,911,649
$395,010 6,095,852 $95,143 4,999 $51,679 16,779 $7,670 - $395,010
6,095,852
kWh
$95,143
4,999
kW-months/year
$51,679
16,779
MMBtu
$7,670
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost Electricity Usage Electricity Demand Natural Gas Ancillary Material Cost