Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2024 |
Principal Product | Plumbing Fixtures |
NAICS | 326191 - Plastics Plumbing Fixture Manufacturing |
SIC | 3088 - Plastics Plumbing Fixtures |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 151,338 |
Annual Production | 110,000 Units |
Production Hrs. Annual | 2,270 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $129,608 | 1,944,360 | kWh | $0.07 |
Electricity Demand | $80,271 | 8,909 | kW-months/year | $9.01 |
Electricity Fees | $1,824 | - | $ | - |
LPG | $436,674 | 20,782 | MMBtu | $21.01 |
Fuel Oil #1 | $877,473 | 31,050 | MMBtu | $28.26 |
TOTAL ENERGY COSTS | $1,525,850 | |||
RECOMMENDED SAVINGS* | $137,941 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Fuel Oil #1 | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Fuel Oil #1 | One-time Revenue or Avoided Cost | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $87,396 Cost: $642,159 |
$60,083 | 900,795 | $27,313 | 3,031 | - | - | - | - | - | - |
$60,083 900,795 kWh |
$27,313 3,031 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.8223 ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE |
Savings: $43,888 Cost: $15,124 |
- | - | - | - | $43,888 | 1,553 | - | - | - | - |
- - kWh |
- - kW-months/year |
$43,888 1,553 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.322 ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL |
Savings: $4,022 Cost: $1,805 |
- | - | - | - | - | - | - | - | $4,022 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$4,022 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $2,282 Cost: $4,696 |
$1,331 | 19,964 | $951 | 106 | - | - | - | - | - | - |
$1,331 19,964 kWh |
$951 106 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $137 Cost: $172 |
$137 | 2,051 | - | - | - | - | - | - | - | - |
$137 2,051 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $122 Cost: $476 |
$71 | 1,059 | $51 | 6 | - | - | - | - | - | - |
$71 1,059 kWh |
$51 6 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7144 INSTALL SPECTRAL REFLECTORS / DELAMP |
Savings: $94 Cost: $52 |
$30 | 445 | $22 | 2 | - | - | $42 | - | - | - |
$30 445 kWh |
$22 2 kW-months/year |
- - MMBtu |
$42 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $137,941 Cost: $664,484 |
$61,652 | 924,314 | $28,337 | 3,145 | $43,888 | 1,553 | $42 | - | $4,022 | - | $61,652 924,314 kWh |
$28,337 3,145 kW-months/year |
$43,888 1,553 MMBtu |
$42 - $ |
$4,022 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Fuel Oil #1 | One-time Revenue or Avoided Cost | Primary Product | Electricity Usage | Electricity Demand | Fuel Oil #1 | One-time Revenue or Avoided Cost | Primary Product |