Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Arizona State University |
---|---|
Assessment Year | 2024 |
Principal Product | fleet vehicles |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $1,000,000-$5,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 23,000 |
Annual Production | 300 Units |
Production Hrs. Annual | 3,012 |
Location (State) | NV |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $26,823 | 269,180 | kWh | $0.10 |
Electricity Demand | $6,752 | 807 | kW-months/year | $8.37 |
Electricity Fees | $1,872 | - | $ | - |
Natural Gas | $15,601 | 957 | MMBtu | $16.30 |
Fuel Oil #1 | $138,297 | 6,283 | MMBtu | $22.01 |
Fuel Oil #2 | $153,803 | 7,961 | MMBtu | $19.32 |
Other Energy | $2,229 | 1 | MMBtu | $2,229.00 |
TOTAL ENERGY COSTS | $345,377 | |||
RECOMMENDED SAVINGS* | $46,718 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $35,167 Cost: $204,030 |
$35,906 | 360,501 | $2,845 | 340 | - | - | $(-3,584) | - |
$35,906 360,501 kWh |
$2,845 340 kW-months/year |
- - MMBtu |
$(-3,584) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $5,201 Cost: $936 |
- | - | - | - | $5,201 | 319 | - | - |
- - kWh |
- - kW-months/year |
$5,201 319 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,406 Cost: $6,171 |
$3,956 | 39,719 | - | - | - | - | $450 | - |
$3,956 39,719 kWh |
- - kW-months/year |
- - MMBtu |
$450 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7226 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE |
Savings: $1,696 Cost: $1,129 |
$938 | 9,421 | $318 | 38 | $440 | 27 | - | - |
$938 9,421 kWh |
$318 38 kW-months/year |
$440 27 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.6211 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES |
Savings: $248 Cost: $144 |
$131 | 1,319 | $117 | 14 | - | - | - | - |
$131 1,319 kWh |
$117 14 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $46,718 Cost: $212,410 |
$40,931 | 410,960 | $3,280 | 392 | $5,641 | 346 | $(-3,134) | - | $40,931 410,960 kWh |
$3,280 392 kW-months/year |
$5,641 346 MMBtu |
$(-3,134) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Ancillary Material Cost |