IAC logo
IAC Assessment: AT0045
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: AT0045
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center North Carolina A&T
Assessment Year 1986
Principal Product METAL HEAT TREATING
NAICS n/a
SIC 3398 - Metal Heat Treating
Sales $1,000,000-$5,000,000
# of Employees 70
Plant Area (Sq.Ft.) 0
Annual Production 4,000,000 Pieces
Production Hrs. Annual 8,400
Location (State) NC
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $201,120 4,073,271 kWh $0.05
Natural Gas $212,248 36,285 MMBtu $5.85
TOTAL ENERGY COSTS $413,368
RECOMMENDED SAVINGS* $107,266 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $94,449
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,281
Cost:
$4,444
$2,281 47,479 - - $2,281
47,479
kWh
-
-
MMBtu
02: 2.1131 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC Savings:
$12,817
Cost:
$2,000
- - $12,817 2,191 -
-
kWh
$12,817
2,191
MMBtu
03: 2.2511 INSULATE BARE EQUIPMENT Savings:
$2,194
Cost:
$100
- - $2,194 375 -
-
kWh
$2,194
375
MMBtu
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$78,041
Cost:
$50,000
$161,872 3,359,906 $(-83,831) (-14,330) $161,872
3,359,906
kWh
$(-83,831)
(-14,330)
MMBtu
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT Savings:
$11,209
Cost:
$5,000
- - $11,209 1,916 -
-
kWh
$11,209
1,916
MMBtu
06: 2.7229 AIR CONDITION ONLY SPACE NECESSARY Savings:
$724
Cost:
$2,000
$724 14,654 - - $724
14,654
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$107,266
Cost:
$63,544
$164,877 3,422,039 $(-57,611) (-9,848) $164,877
3,422,039
kWh
$(-57,611)
(-9,848)
MMBtu
TOTAL IMPLEMENTED Savings:
$94,449
Cost:
$61,544
$164,877 3,422,039 $(-70,428) (-12,039) $164,877
3,422,039
kWh
$(-70,428)
(-12,039)
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas