Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
IAC Center | Boise State University |
---|---|
Assessment Year | 2014 |
Principal Product | Exterior Signs |
NAICS | 332323 - Ornamental and Architectural Metal Work Manufacturing |
SIC | 3993 - Signs And Advertising Specialities |
Sales | $5,000,000-$10,000,000 |
# of Employees | 91 |
Plant Area (Sq.Ft.) | 60,000 |
Annual Production | 4,000 Pieces |
Production Hrs. Annual | 2,016 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $30,224 | 584,480 | kWh | $0.05 |
Electricity Demand | $13,860 | 2,463 | kW-months/year | $5.63 |
Electricity Fees | $195 | - | $ | - |
Natural Gas | $41,495 | 5,828 | MMBtu | $7.12 |
TOTAL ENERGY COSTS | $85,774 | |||
RECOMMENDED SAVINGS* | $28,831 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $21,058 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $65 Cost: $132 |
$65 | 1,270 | - | - | - | - |
$65 1,270 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,413 Cost: $8,156 |
$5,413 | 104,682 | - | - | - | - |
$5,413 104,682 kWh |
- - kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $89 Cost: $113 |
$58 | 1,130 | $30 | 5 | - | - |
$58 1,130 kWh |
$30 5 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $374 Cost: $15 |
$249 | 4,816 | $125 | 22 | - | - |
$249 4,816 kWh |
$125 22 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $6,366 Cost: $24,165 |
- | - | - | - | $6,366 | 940 |
- - kWh |
- - kW-months/year |
$6,366 940 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $8,299 Cost: $50 |
- | - | - | - | $8,299 | 1,167 |
- - kWh |
- - kW-months/year |
$8,299 1,167 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $7,773 Cost: $13,800 |
- | - | - | - | $7,773 | 1,093 |
- - kWh |
- - kW-months/year |
$7,773 1,093 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $452 Cost: $340 |
- | - | - | - | $452 | 64 |
- - kWh |
- - kW-months/year |
$452 64 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $28,831 Cost: $46,771 |
$5,785 | 111,898 | $155 | 27 | $22,890 | 3,264 | $5,785 111,898 kWh |
$155 27 kW-months/year |
$22,890 3,264 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $21,058 Cost: $32,971 |
$5,785 | 111,898 | $155 | 27 | $15,117 | 2,171 | $5,785 111,898 kWh |
$155 27 kW-months/year |
$15,117 2,171 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |