Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | Boise State University |
---|---|
Assessment Year | 2014 |
Principal Product | Railroad Equipment |
NAICS | 336510 - Railroad Rolling Stock Manufacturing |
SIC | 3743 - Railroad Equipment |
Sales | $100,000,000-$500,000,000 |
# of Employees | 536 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 55 Pieces |
Production Hrs. Annual | 5,460 |
Location (State) | ID |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $299,553 | 6,543,278 | kWh | $0.05 |
Electricity Demand | $98,857 | 14,437 | kW-months/year | $6.85 |
Electricity Fees | $3,642 | - | $ | - |
Natural Gas | $296,026 | 54,996 | MMBtu | $5.38 |
TOTAL ENERGY COSTS | $698,078 | |||
RECOMMENDED SAVINGS* | $72,954 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,861 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $17,744 Cost: $26,100 |
- | - | - | - | $17,744 | 3,296 |
- - kWh |
- - kW-months/year |
$17,744 3,296 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7495 INSTALL REPLACEMENT DOORS |
Savings: $4,556 Cost: $17,436 |
- | - | - | - | $4,556 | 846 |
- - kWh |
- - kW-months/year |
$4,556 846 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1336 INSTALL EQUIPMENT TO UTILIZE WASTE FUEL |
Savings: $16,582 Cost: $31,134 |
- | - | - | - | $16,582 | 3,080 |
- - kWh |
- - kW-months/year |
$16,582 3,080 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $2,961 Cost: $10,130 |
- | - | - | - | $2,961 | 550 |
- - kWh |
- - kW-months/year |
$2,961 550 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $10,250 Cost: $11,371 |
- | - | - | - | $10,250 | 1,904 |
- - kWh |
- - kW-months/year |
$10,250 1,904 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $3,963 Cost: $937 |
$3,289 | 71,382 | $674 | 98 | - | - |
$3,289 71,382 kWh |
$674 98 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $16,898 Cost: $2,032 |
$12,393 | 270,712 | $4,505 | 658 | - | - |
$12,393 270,712 kWh |
$4,505 658 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $72,954 Cost: $99,140 |
$15,682 | 342,094 | $5,179 | 756 | $52,093 | 9,677 | $15,682 342,094 kWh |
$5,179 756 kW-months/year |
$52,093 9,677 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,861 Cost: $2,969 |
$15,682 | 342,094 | $5,179 | 756 | - | - | $15,682 342,094 kWh |
$5,179 756 kW-months/year |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Electricity Usage | Electricity Demand | Natural Gas |