Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center Boise State University
Assessment Year 2014
Principal Product Heating/Cooling Coils
NAICS 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipmen
SIC 3585 - Refrigeration And Heating Equipment
Sales $10,000,000-$50,000,000
# of Employees 155
Plant Area (Sq.Ft.) 55,000
Annual Production 1,820 Pieces
Production Hrs. Annual 4,188
Location (State) WA
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $93,882 1,193,409 kWh $0.08
Electricity Demand $27,618 4,091 kW-months/year $6.75
Electricity Fees $314 - $ -
Natural Gas $37,766 4,743 MMBtu $7.96
TOTAL ENERGY COSTS $159,579
RECOMMENDED SAVINGS* $34,282 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $25,335
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas
$ kWh $ kW-months/year $ MMBtu
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,472
Cost:
$8,031
$2,059 26,061 $413 61 - - $2,059
26,061
kWh
$413
61
kW-months/year
-
-
MMBtu
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$17,441
Cost:
$42,000
$17,441 220,776 - - - - $17,441
220,776
kWh
-
-
kW-months/year
-
-
MMBtu
03: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS Savings:
$4,279
Cost:
$17,525
$(-398) (-5,040) - - $4,677 592 $(-398)
(-5,040)
kWh
-
-
kW-months/year
$4,677
592
MMBtu
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,955
Cost:
$450
$1,955 24,752 - - - - $1,955
24,752
kWh
-
-
kW-months/year
-
-
MMBtu
05: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$1,973
Cost:
$3,120
$1,973 24,974 - - - - $1,973
24,974
kWh
-
-
kW-months/year
-
-
MMBtu
06: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$4,668
Cost:
$9,641
- - - - $4,668 587 -
-
kWh
-
-
kW-months/year
$4,668
587
MMBtu
07: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,494
Cost:
$175
$1,494 18,907 - - - - $1,494
18,907
kWh
-
-
kW-months/year
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$34,282
Cost:
$80,942
$24,524 310,430 $413 61 $9,345 1,179 $24,524
310,430
kWh
$413
61
kW-months/year
$9,345
1,179
MMBtu
TOTAL IMPLEMENTED Savings:
$25,335
Cost:
$53,776
$24,922 315,470 $413 61 - - $24,922
315,470
kWh
$413
61
kW-months/year
-
-
MMBtu
Savings
Cost
$ kWh $ kW-months/year $ MMBtu
Electricity Usage Electricity Demand Natural Gas Electricity Usage Electricity Demand Natural Gas